- Laboratory >
- Laboratory medicine >
- Automatic biochemistry analyzer
Automatic biochemistry analyzers
Sample volume: 0.1 ml
Weight: 2.5 kg
Length: 175 mm
The dimensions are very tight and fit into any clinic.The rotors carry a QR reader to identify them easily and without errors, the analysis procedure requires less than 1 minute of work and the results appear in a maximum of 13 minutes. ...
Throughput: 100 p/h
Sample volume: 0.045 ml
Number of sample positions: 9, 12, 42 unit
Test modes: - Routine, Batch, Emergencies (STAT) Computer: - Built-in with touchscreen Printer: - Built-in thermal printer, external printer optional Sample pre-dilution: - Yes Calibrator pre-dilution: - No Reaction Cuvettes: - Disposable Cuvette ...
Dialab
Throughput: 600, 360 p/h
Number of tests: 500 unit
Sample volume: 0.001 ml - 0.05 ml
End-point, Fixed time, Kinetic, 45 non-disposable optical glass cuvette SPECIFICATIONS SYSTEM SPECIFICATIONS Methods: - End-point, fixed time, kinetic, ISE Module: - Original, Na, K, CI and optional CO2 REAGENT UNIT Reagent ...
BILIMSEL TIBBI ÜRÜNLER
Throughput: 150 p/h
Sample volume: 0.002 ml - 0.3 ml
Number of sample positions: 20 unit
... ’s the smallest analyzer with the greatest potential in the category, ideal for daily routine and special routine. The analyzer weighs just 19 kg and it can ensures up to 150 tests/hour. Piccolo Chem ...
Gesan Production
Number of tests: 3,700 unit
Sample volume: 0.2 ml - 3 ml
The quality control data and quality control charts can be printed Performance Characteristics Using the overall cast aluminum optical path system, strong anti-interference ability and high reliability Adopt scientific circuit ...
Fully Automatic Random Access Bench Top Clinical Chemistry Analyzer TECHNICAL SPECIFICATIONS THROUGHPUT Up to 300 photometric tests/hr or up to 480 tests/hour with optional ISE module SAMPLES ...
Trivitron Healthcare
Throughput: 800 p/h
Sample volume: 0.0001 ml
Reagent volume: 0 ml
... maintenance free •Only alkaline cleaning solution is needed for daily use, reducing the use-cost 3.Intelligent service •Automatic report review •The remote data center with remote data collection, analysis and ...
Throughput: 800, 1,400 p/h
Number of sample positions: 27 unit
Reagent volume: 0.02 ml - 0.03 ml
... high pressure flushing, 1.5 mu minimum sample weight, 1.5 l - 35 mu, 0.1 mu l l progressive Sample processing: automatic dilution, automatic measurement Emergency samples: random insertion Reagent ...
Sunostik Medical Technology
Throughput: 200 p/h
Number of reagent positions: 27, 44 unit
PC-controlled fully automated biochemistry analyzer Fully automated dilutions capability, pre-dilutions, dispense reagents by single well or 8-way multiple well reagent ...
Awareness Technology
Throughput: 300 p/h
Number of reagent positions: 60 unit
Weight: 50 kg
InCCA is a clinical chemistry autoanalyzer for medium-volume laboratories. It is an open and random access system. Analyzer with automatic cuvette washer, its software interface is easy to use, the lowest ...
Diconex
Throughput: 300 p/h
Sample volume: 0.02 ml - 0.35 ml
Number of sample positions: 60 unit
Fully automated, random access, discrete, benchtop chemistry analyzer for clinical diagnostics with STAT priority 300T/H 80Reagent positions 60 sample positions 160 reaction cuvettes Cost-efficient: 1. ...
Shenzhen Prokan Electronics Inc
Throughput: 300 p/h
Reagent and Sample Tray : Loading more reagent and sample at same time. Intelligent QC Management : Enable QC rules that suit you. Bi-Directional LIS Connectivity : Ensures superior lab process. Specially Designed Mixer : Ensure Homogeneous ...
Medconn Ranos® biochemical reagents have been strictly evaluated by Hitachi and used in conjunction with Hitachi LABOSPECT 008 AS automatic biochemical analyzer to provide ...
Number of tests: 235 unit
Sample volume: 0.018 ml
Weight: 8 kg
... range - Automatic via filter wheel Filters - 340, 405, 450, 505, 546, 578, 630 and 670nm interference type Bandwidth - 10 nm (± 2nm) Reading error - ± 5% at 0.10 A ± 2% at 1.00 A ± 2% at 2.00 A Light source - Halogen ...
Micro Lab Instruments
Throughput: 300, 190 p/h
Sample volume: 0.002 ml - 0.3 ml
Number of sample positions: 60 unit
... available. 60 refrigerated positions for reagents with removable trays. 60 sample positions. Continuous loading of samples. Automatic and programmable start-up of the system. Intuitive and informative user interface allow ...
Sclavo Diagnostics International
Throughput: 100 p/h
... productivity of the lab. The easy automated testing improves the workflow and mitigates manual labour, together with its cost-effectiveness, making it possilble to bring benefits of automatic chemistry ...
Genrui Biotech Inc.
Throughput: 120 p/h
Sample volume: 0.002 ml - 0.1 ml
Number of sample positions: 30 unit
... Sample Probe: Liquid level detection, anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle Probe Cleaning: Automatic washing for both interior and exterior Others Water ...
Jinan Kinghawk Technology Co., Ltd.
Weight: 122 kg
Length: 640 mm
Width: 650 mm
Automated blood culture system LB-10ABC is a fully automated non-invasive microbial culture and detection equipment. Inbuilt optical detection algorithm tracks the intensity of florescence periodically. ...
Labotronics Scientific Ltd
Throughput: 100 p/h
Sample volume: 0.002 ml - 0.1 ml
Number of sample positions: 12 unit
... Sample Management System: 12 sample positions always available NEW: Very Intuitive and easy-to-use interface NEW: 1st Analyser fully developed by the 3 companies of the BIOLABO GROUP main features: • Fully ...
BIOLABO GROUP
Throughput: 600 p/h
Constant through-put 600T/H, can be extended with ISE module. Grating after spectroscopy technolog to make a more accurate result. Advanced solid direct heating technology raises the température quickly and free of maintenance.
GUANGZHOU EXCBIO TECHNOLOGY CO.,LTD
Throughput: 450, 300 p/h
Number of sample positions: 79 unit
Number of reagent positions: 80 unit
13 wavelength options, 340 -800 nm Automatic cleaning system; carrying rate = 0. 05% Automatic sample dilution: Pre-dilution and post-dilution Water bath reaction tray, 37±0.1 C
Medicalsystem Biotechnology Co., Ltd.
Sample volume: 0.002 ml - 0.06 ml
Weight: 210 kg
Length: 1,110 mm
Large Capacity • 120 Reaction vessel • 105 Sample positions • 90 Reagent positions • More than 5 directional methods • 2 analysis methods: Colorimetry, turbidimetry Reliable Result • 13 wavelengths, provide more optimum λMax ...
Throughput: 120, 128 p/h
Sample volume: 0.01, 0.05 ml
Number of sample positions: 1 unit
DRI-CHEM from FUJIFILM is a dry chemistry analyzer which can perform multiple test parameters of Clinical Chemistry. It has a built-in auto-pipetting system, requires no calibration and no water, providing easy preparation ...
The Automatic Biochemistry Analyzer can measure various biochemical indicators by analyzing the blood and other body fluids. Combined with other clinical data, its comprehensive ...
Throughput: 50 p/h - 260 p/h
Sample volume: 0.001 ml - 0.1 ml
Number of sample positions: 50 unit
... ouvettes awailable on request 8 channels automatic washing system, waste liquid collected by high concentration and low concentratian respectively, automatically dry cuvette, water consumption is 2-4L/H Automatic ...
Throughput: 50 p/h - 200 p/h
Sample volume: 0.001 ml - 0.1 ml
Number of sample positions: 40 unit
... glass cuvettes available on request 5 channels automatic washing cuvette system; waste liquid collected by high concentration and low concentration respectively; automatically dry cuvette Automatic ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining