- Laboratory >
- Hematology >
- Benchtop coagulation analyzer
Benchtop coagulation analyzers
Throughput: 220, 110, 40, 25 p/h
Number of reagent positions: 29 unit
Weight: 75 kg
Highly integrated auto system Original tube & autoloader Reliable Precise control module Three detection methods with high sensitivity Efficient Independent STAT position One position for multiple items Safe Anti-pollution ...
Length: 33 cm
Width: 13.7 cm
Height: 31 cm
... Software Display: Big LCD screen, graph display, function keyboard Printer: Unique printable random reports and "overall coagulation reporter". Internal printer; saving and printing reference data and curve automatically
Throughput: 100 p/h
Sample volume: 0.012 ml - 0.1 ml
Number of sample positions: 8 unit
Sample Tray 36 Probe heating YES liquid level detection YES Reaction System Incubation Temperature 37°C±0.1 Reaction Cuvette 200 Operation System STAT Faction - YES Bar Code Reader - Optional Operating ...
Zircon Biotech Co., Ltd
Weight: 40 kg
Length: 85 cm
Width: 60 cm
Clotting, chromogenic, immunological Quarter test volume (75μL) high speed testing Biphasic waveform analysis Profile testing in batch or random access Single or double determination Automatic reflex testing Sample 3 x 15 ...
Sample volume: 0.15 ml - 0.3 ml
Number of sample positions: 5 unit
Number of reagent positions: 6 unit
... (FIB) TECHNICAL SPECIFICATIONS General specifications: System Random Access, Bench top, Automated Haemostasis analyzer Measuring principle Clotting & Immunologic Operation External Windows based ...
High sensitivity for the determination of the essential tests of the plasma phase of hemostasis (PT, PTT, fibrinogen, factors etc.). Turbo-Densidométrico system of clot detection, electronic time control with precision of 0.1 seconds ...
RAL, Tecnica para el Laboratorio S.A.
Number of sample positions: 2 unit
Number of reagent positions: 20 unit
Weight: 1 kg
Quarter method Auto-start function Maintainance free Technical Specifications Optic cell: Photometer with pulsed 405 nm LEDs Calibration points: 5 Result conversion: Seconds, INR, %, Ratio, Units (mg/dL, g/L, ng/mL) Incubation ...
Dialab
Number of sample positions: 16 unit
Number of reagent positions: 7 unit
RAM stores 100,000+ results Tests can be started with a pipettor Optical method open system, strong compatibility Performance Characteristics Well design incubation area, operation conveniently 2 measurement channels
Throughput: 140, 160 p/h
Number of sample positions: 6, 5 unit
Number of reagent positions: 6, 11 unit
Fully automatic, improve working efficiency. Complete diagnosis data for clinic, LIS system available, easy to manage. Fully automatic sampling and testing system, ensure the consistency and accuracy of the test results. Refrigerated ...
Paramedical srl
Number of reagent positions: 3 unit
Weight: 25 kg
Length: 360 mm
Adopt photoelectric turbidimetry method; monitor the process of clotting coagulation. Special intelligent software, no influence from pathological sample during the test. Open reagent systems Micro reagent and sample ...
Sample volume: 0.075, 0.3 ml
Weight: 5.6 kg
Width: 14 cm
Semi-automatic Single channel coagulometer Printout of the graph and results On-board storage capability up to 20 assays Open system with user friendly software All methods creatable, editable, copy and delete Automated ...
Micro Lab Instruments
Throughput: 300 p/h
High-throughput, random-access hemostasis analyzer for mid/high-volume laboratories performing routine and special assays. Innovative system ensures efficient, reliable results with built-in QC features. ...
Diagon Ltd.
CA52 is a touch screen semi-automatic coagulation analyser with 4 independent working channels. The number of samples and reagents required for testing is small and cost saving. Principle: Clotting, ...
Genrui Biotech Inc.
Sample volume: 0.2 ml
Number of sample positions: 16, 8 unit
Reagent volume: 0.05 ml - 0.2 ml
... 6. precision: CV ≤3% 7. speed: ≤300s(depend on setting) Test itmes Main test: FIB Others: Hep ProC ProS Coagulation factor II,V,VII,VIII,IX,X,XI,XII AT-III AT RepT RVVT RVVCT RVVRT LA
Jinan Kinghawk Technology Co., Ltd.
... Semi-automatic Coagulometer Analyzer is suitable for the analysis of blood plasma coagulation and anticoagulation, fibrinolytic and anti-fibrinolytic function. The equipment is used ...
Weight: 2.5 kg
Length: 31 cm
Width: 12.5 cm
... On of the best-selling coagulometers • All routine Analysis: • PT (Prothrombin Time) • APTT (Activated Partial Thromboplastin Time) • TT (Thrombin Time) • FIB (Fibrinogen) • And 4 free positions for ...
BIOLABO GROUP
Throughput: 320 p/h
Number of sample positions: 40 unit
Number of reagent positions: 20 unit
... result. The present blood coagulation analyzer have TWO detection mode: 1, Optical coagulation analysis technic---low cost, but uncertainty at special samples like jaundice, lipid ...
Shenzhen Thistory Bio-Medical Co., Ltd
Sample volume: 0.02 ml - 0.04 ml
Number of sample positions: 12, 24 unit
Reagent volume: 0.02 ml
The blood coagulation analyzer adopts the principle of optical colorimetry for detection. After the reagent is mixed with the plasma, fibrinogen is converted into fibrin and coagulated, which leads to ...
Length: 240 mm
Width: 230 mm
Height: 100 mm
LEPU FastRing FR1000 can be applied for Quickly detecting the function of residual platelet aggregation and predict the risk of thrombosis and monitoring the efficacy of antiplatelet drugs and guide the use of drugs. Features Quickly ...
Number of sample positions: 32 unit
Reagent volume: 0.05 ml - 0.1 ml
Number of reagent positions: 4 unit
Technical Specifications: Test Menu: PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), TT (Thrombin Time), FBG (Fibrinogen Concentration), Clotting Factors Clotting ...
Sample volume: 0.05 ml - 0.15 ml
Reagent volume: 0.05 ml - 0.2 ml
Features 1. Semi-automatic blood coagulation instrument, four channels 2. Test items: prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FIB), thrombin time (TT), other coagulation ...
Weight: 5 kg
Length: 43 cm
Width: 37 cm
We present 5 channels coagulometer CC-4000, which executes all basic coagulational determination by chronometrical method, method of the usage of chromogenic substrate and immunochemical method (D-dimer). Range of ...
Throughput: 150 p/h
Number of sample positions: 25 unit
Number of reagent positions: 24 unit
The Ci-120x is a fully automated benchtop coagulation analyzer with high-end features designed for low to medium volume laboratories. Despite its compact size, the instrument is comparable ...
Weight: 5 kg
Length: 15 cm
Width: 35 cm
Clot is a single-channel coagulometer, fully controlled by built-in microprocessor and designed to perform all routine tests such as PT, aPTT, Fibrinogen and clotting factors. It has a 37-degree dry incubation block with 18 samples capacity. ...
Number of sample positions: 8 unit
Number of reagent positions: 2 unit
Colorimetric cuvette: micro cuvette Temp. control accuracy: 37°C±0.2°C Detecting element: imported silicon battery Calculative item: S,INR,R,g/L Repeatability: ≤3% with standard Q.C material Test Channel: 1 channel, 37°C±0.2°C
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining