- Surgery unit >
- Anesthesia >
- Breathing circuit
Breathing circuits
... Features: 1.Made of medical polymer material, which is transparent and soft. 2.Special design of single limb breathing circuit with double lumen. Use one tube of inhaling and exhaling, which can ...
... anesthesia mask, breathing filter and respiratory machine, offering a passage for clinic gas delivery, such as anesthetic gas, oxygen gas. Advantages: 1.Smooth inner wall, not easy to cause water vapor residue 2.Can ...
Single-use respiration loop Single-use respiration loops are in combination with endotracheal tube or anesthesia mask, breathing filter and respiratory machine, offering a passage for clinic gas delivery, such as anesthetic ...
Breathing Circuits belongs to respiratory anesthesia or endotracheal tube for ventilation products, including anesthesia type, breathing type and sleep type, etc. Intended Use The ...
... patient interfaces, as well as the BPAP-H series non-invasive ventilator and its matching mask. It consists of a heating circuit, humidification chamber, and elbow pipe.
... of Flextube™ circle breathing systems with a unique clip feature. When used with Intersurgical recessed connectors an airtight fit is achieved, ensuring there are no leaks or disconnections. A range of 22mm Flextube ...
T-Piece Circuit for Infant with PEEP Valve 25
... use ventilator circuit is designed specifically for use on bag-valvemask resuscitators and ventilators without demand breathing or patient triggered ventilation modes. The 01CV8015-Cs single patient-use ...
Soft, quiet EVA sheath Intuitive, one-handed operation Irrigation port, with one-way valve Advanced proximal seal Double-swivel elbow Cyclonic cleaning chamber
GBUK Group
Our tubing sets have been specially developed for single use in combination with Medijet® and Miniflow®. Both products are very well tolerated by premature infants and newborns and are equally effective in application.
... first variable PEEP device compatible with all major resuscitation devices The NeoPEEP® single use neonatal resuscitation circuit lets you regulate the Functional Residual Capacity by providing a consistent Positive ...
... Coaxial Breathing Circuit with Water Trap helps deliver oxygen and anaesthetic gases to patients and eliminates carbon dioxide, while removing clutter from the anaesthesia ...
... desired temperature, moisture, and warming fluid. ADVANTAGES Fluid warming through the heated wire integrated in the circuit Keeps fluids warm, between 30 ~ 36℃ Automatic system to make and maintain desired temperature ...
ACE Medical
Double hélix heating wire ,closed-loop process makes sure the heating is uniform, and ensures humidification and minimizes condensation. Fit disposable elbow joints to prevent cross-infection.
The Valveless One - Circuit is compatible with Masks that include a leak and high flow therapy. This is the non heated version- the heated Version is also available. Comes in a 10-Pack
... /Un-Extensible Corrugated Pipe ●Heat And Moisture Ex-Changer ●Face Mask ●90° Elbow ●Straight Connector ●Face Mask ●Breathing Bag ●Etc. Certificate ISO13485
... and leakage in the circuit. High performance water trap. 2 gas sampling port on Y-connector. The circuit is manufactured in 10,000 class clean room. The product complies with ISO 13485:2016 ...
USM Healthcare Medical Devices Factory
Closed suction system. It could be use for 24 hours. It is prevent contamination.
Bıçakcılar
22mm Breathing System for Dräger Oxylog 2000, 3000, 3000 Plus. Universal catheter mount with suction tube, flower sensor, exhalation valve. Specifications 22mm Application: Detach for tracheal tube directly. / Connect ...
Besmed Health Business
Includes: - 01 1.30 m proximal silicone tube (RC653); - 01 adaptor 14 mm out x 15 mm out (RC611); - 01 polycarbonate Jackson connector (RC632); - 02 polycarbonate drain jars (RC637); - 01 45 cm corrugated tube (TC332); - 04 60 cm ...
Unitec Hospitalar
allows continuous ventilation during suctioning procedure, preventing oxygen desaturation and loss of lung volume closed circuit preventing cross contamination and infection double swivel elbow connector MDI port for ...
Anesthesia Breathing Circuits • Made Of EVA material. • Product composition has connector, face mask, extendible tube. • Store under normaltemperature. avoid direct sunlight. Packing: 40 pcs/carton Carton ...
With a highly lightweight flexible tube, which prevents lateral pressure and minimizes drag from the breathing circuit. Available with double swivel elbow for more convenience while operating.
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining