Femoral Stem (Cemented) REF. NO (SS) - REF. NO (CoCrMo Alloy) - SIZE (mm) 7021-0700 7023-0700 7 7021-0800 7023-0800 8 7021-0900 7023-0900 ...
Titanium total hip prosthesis Medium necks BM0 BM1 BM2 BM3 BM4 BM5 Long necks BM0 BM1 BM2 BM3 BM4 BM5
Femoral stem length: 125, 149 mm
Femoral stem offset: 38, 45, 50, 36 mm
... survivorship for aseptic loosening with follow-up ranging out to 15 years. Design Collarless, polished and double tapered implant that utilises a world-class stem design. Instrumentation is designed for axial ...
... head through 12/14 tapered male trunnion. 2. The cemented femoral stem is highly polished, double tapered, collarless design and is intended to be used with bone cement (cemented fixation). 3. The ...
Femoral stem length: 110 mm
CCD angle: 135 °
The Thompson Surgival prosthesis is indicated for femoral neck fractures in which internal fixation is not recommended. This is typically found in older patients or those with limited mobility. Specifications Manufactured ...
Femoral stem length: 128, 149 mm
Femoral stem offset: 36, 38, 45, 50 mm
Femoral head diameter: 40 mm - 60 mm
... clinical outcomes in cemented total hip replacement. The Avanteon® Hip System is the first total hip replacement system to be included in the pilot phase of Beyond Compliance. ...
JRI Orthopaedics
1.Severe varus/valgus deformity with severe flexion contractrue,and need to release bilateral accessory ligaments completely. 2.Severe and uncorrected imbalance of flection gap,and lead to cam separation in non-limited design. 3.The ...
Femoral head diameter: 22.2 mm - 32 mm
CCD angle: 128 °
The EMERGENCE cemented femoral stem has been designed following the Charnley-Kerboull experience. EVOLUTIS wished to simplify its use on a everyday basis and changed the original neck management system (combination ...
Often used for trauma cases. Wide size range of outside diameter, inside diameter is 28 mm. Ideal in those cases when femoral head cannot be saved.
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining