- Secondary care >
- Orthopedic surgery >
- Cementless femoral stem
Cementless femoral stems
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
TrendHip® Stem system – Combining traditional features The TrendHip® design concept combines the traditional features of a straight tapered and fully surface coated cementless hip stem. ...
TRJ® Hip stem – Trochanter retaining joint replacement The TRJ® hip prosthesis stem is implanted withoutcement. The stem design is based on many years of experience with a conical ...
... requirements of advanced revision surgeries. The result is a platform of implants with a cementless and cemented Monobloc stem option, followed by corresponding design principles for a modular concept ...
Spec. - A(mm) - B(mm) - C(mm) - D(mm) - F(mm) 1# - 51 - 35.4 - 27.2 - 7 - 130 2# - 54 - 37.7 - 28.5 - 8 - 140 3# - 54 - ...
Paragon is a cementless, bi-planar wedge stem which has added advantageous features to the design to improve upon similar wedge stems on the market. The evolutionary Paragon stem ...
... length with 10 sizes • 250mm Right and Left with 9 sizes Coating: • Titanium Coating Design of Cementless Long Stem Overview: The cementless long stem is designed ...
... Titanium Ti6Al4V Eli Size: • 8 available sizes Coating: • Titanium Coating Design of Cementless Short Stem Overview: The cementless short stem is engineered ...
... Available in 8 diameters • With height starting from 130mm to 180mm Design of HA Coated Cementless Stem Overview: The HA (hydroxyapatite) coated cementless stem ...
CCD angle: 126, 135 °
• The range of stems allows the implant to be matched to all bone sizes. • All cementless implants are coated with a titanium plasma+HA coating. • Taper 12/14, completely conical form.
Femoral stem length: 7.5, 13.5 mm
Acetabular cup diameter: 22 mm - 28 mm
Femoral head diameter: 42 mm - 62 mm
Femoral Stem Dual Coated Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Bipolar Head Acetabular Screw Acetabular Liner (10°) Acetabular ...
Femoral stem length: 55, 25 mm
Femoral stem offset: 17, 9 mm
Acetabular cup diameter: 42 mm - 62 mm
Calcar Replacement Stem Dual Coated (Cementless) SIZE (mm) 25/9 25/11 25/13 35/9 35/11 35/13 35/15 35/16 35/17 45/9 45/11 45/13 55/9 55/11 55/13
Femoral stem length: 11, 17 mm
Monoblock Stem (Cementless) Size 11mm 12mm 13mm 14mm 15mm 16mm 17mm
... motion and reduces potential for femoral fracturing. 3. Coatings available in both Titanium Plasma Spray (TPS) & Hydroxyapatite (HA) to enhance mechanical engagement in bone. 4. Compatible with both metal and ceramic ...
... motion and reduces potential for femoral fracturing. 3. Coatings available in both Titanium Plasma Spray (TPS) & Hydroxyapatite (HA) to enhance mechanical engagement in bone. 4. Compatible with both metal and ceramic ...
Femoral stem length: 68, 135 mm
Femoral stem offset: 24.2, 59.3 mm
CCD angle: 140, 129, 137, 127 °
... individual femoral anatomies by matching patient’s medial curvatures and demonstrating good mid-long term clinical results. Features Inspired by Individual Anatomy Three families, four offset option and CCD angles ...
... rectangular form of the CLP® hip stem assures rotational stability by providing a mechanical interlock with the proximal femoral cortical bone. Unique Contour The unique contour that conforms to the ...
Femoral stem offset: 33.35 mm
CCD angle: 130 °
... are two significant challenges. EMPHASYS™ Femoral Solutions addresses those challenges by providing broad coverage of implant sizes for a variety of femur types. About This Product The EMPHASYS™ ...
Depuy Synthes
Femoral stem length: 28, 61 mm
CCD angle: 132, 127 °
... by creating a higher conformity between the implant and the femoral cortices, leading to a larger area of contract. Enhanced proximal-distal proportions Distal-only engaged femoral stems ...
Stryker
CCD angle: 135, 127 °
... SMS femoral stem has been designed to meet today’s THA challenges in a growing patient population . The stem is designed to achieve a more physiological proximal load transfer and ...
Medacta
Femoral Hip Stem incorporates a traditional press fit tapered-wedge design with titanium plasma coating proximally for stable fixation. The instruments are well suited for various surgical ...
Femoral stem length: 171, 91 mm
... available. Extra-medullary part evolves with stem’s size: Lateralization and CCD angle are larger on larger sizes. High Offset option collarless — 8 sizes available. Collar starting in the internal axis of the stem: ...
Amplitude Surgical
Femoral stem length: 165, 115 mm
Femoral stem offset: 53.5, 34.7 mm
CCD angle: 135, 126 °
... Bone preserving Anatomically shaped stems necessitate anatomically shaped instruments. The compressors in the SP-CL System follow exactly the anatomical design of the stems and prepare the bone bed for ...
Waldemar Link
CCD angle: 135, 127 °
... hip stems has an established clinical history. Each Profemur® hip stem offers its own philosophy to provide fixation and replace bone anatomy. Tapered wedge stem philosophy Designed ...
Femoral stem length: 95, 135 mm
Femoral stem offset: 32, 53 mm
The UTF (United Tapered Fit) Reduced Stem Primary Hip System offers a dual taper wedge stem design. This taper-fit concept is intended to engage the cortex in the stem corners to provide ...
Femoral stem length: 129, 191 mm
CCD angle: 123, 131 °
... non-cemented stem is based on the principles of biological cortical anchorage, as described by Prof. Dr. K. Zweymüller. This stem design has been in clinical use for more than 30 years. With its conical ...
Femoral stem length: 95, 145 mm
Femoral stem offset: 38.5 mm
CCD angle: 135 °
TBG Cementless Hip Stem System
Double Medical Technology
Femoral stem length: 94, 129 mm
Femoral stem offset: 31.6, 60.9 mm
The design philosophy of the Alteon® HA Femoral Stem evolved from more than 25 years of clinical use. It features incremental stem sizing, proportional neck geometry, and reduced stem ...
Exactech
... old fracture of the femoral neck, pain from destruction of the femoral head or acetabulum, resulting in impairment of joint function; 2. Patients with avascular necrosis of the femoral ...
CCD angle: 135, 125 °
The progressive trapezoidal geometry enables optimal adaptation of the stem and both anti-translational and anti-rotational fixation that provides perfect primary stability while preventing the hip prosthesis from sinking. Specifications Standard ...
Surgival
... debris secondary to prosthetic impingment. · Double tapper design fits most femoral canal anatomy and preserves more bone stock for revision. · Stepped geometry of the stem surface minimize shear forces ...
Irene Ortho
CCD angle: 130 °
P130® 2/3 Coated femoral stem for the replacement of the natural hip joint during first intention. Range of products: The metaphyseal profile of the stem ensures the implant’s primary ...
C2F Implants
... the hydroxyapatite coating, ensures stability in the long term. 3 options are offered: - Standard Filler stem - TI Filler stem - Collar Filler stem From 8 to 20 Features Conus: 5°42'30'' ...
Biotechni
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining