- Laboratory >
- Hematology >
- Coagulation analyzer
Coagulation analyzers
Sample volume: 0.02 ml - 0.04 ml
Number of sample positions: 12, 24 unit
Reagent volume: 0.02 ml
The blood coagulation analyzer adopts the principle of optical colorimetry for detection. After the reagent is mixed with the plasma, fibrinogen is converted into fibrin and coagulated, which leads to ...
Number of sample positions: 16 unit
Reagent volume: 0.05 ml - 0.1 ml
Number of reagent positions: 2 unit
Technical Specifications: Test Menu: PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), TT (Thrombin Time), FBG (Fibrinogen Concentration), Clotting Factors Clotting ...
Number of sample positions: 32 unit
Reagent volume: 0.05 ml - 0.1 ml
Number of reagent positions: 4 unit
Technical Specifications: Test Menu: PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), TT (Thrombin Time), FBG (Fibrinogen Concentration), Clotting Factors Clotting ...
Sample volume: 0.05 ml - 0.15 ml
Reagent volume: 0.05 ml - 0.2 ml
Features 1. Semi-automatic blood coagulation instrument, four channels 2. Test items: prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FIB), thrombin time (TT), other coagulation ...
Weight: 5 kg
Length: 43 cm
Width: 37 cm
We present 5 channels coagulometer CC-4000, which executes all basic coagulational determination by chronometrical method, method of the usage of chromogenic substrate and immunochemical method (D-dimer). Range of ...
Throughput: 150 p/h
Number of sample positions: 25 unit
Number of reagent positions: 24 unit
The Ci-120x is a fully automated benchtop coagulation analyzer with high-end features designed for low to medium volume laboratories. Despite its compact size, the instrument is comparable to high-end ...
Weight: 5 kg
Length: 15 cm
Width: 35 cm
Clot is a single-channel coagulometer, fully controlled by built-in microprocessor and designed to perform all routine tests such as PT, aPTT, Fibrinogen and clotting factors. It has a 37-degree dry incubation block with 18 samples capacity. ...
Number of sample positions: 8 unit
Number of reagent positions: 2 unit
Colorimetric cuvette: micro cuvette Temp. control accuracy: 37°C±0.2°C Detecting element: imported silicon battery Calculative item: S,INR,R,g/L Repeatability: ≤3% with standard Q.C material Test Channel: 1 channel, 37°C±0.2°C
Thermostat at 37°C for 21 reaction cuvettes and two reagent vials. The clot detection is done for positive and negative O.D., in accentuated fibrinogenemias. It may store up to 10 different methods in memory including their calibration ...
... for a number of manufacturers of coagulation clottin agents The main test items PT: prothrombin time APPT: activated partial thromboplastin time TT: thrombin time FIB: fibrinogen II, V, VII, X: extrinsic coagulation ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining