- Laboratory >
- Laboratory medicine >
- Colon cancer test kit
Colon cancer test kits
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... with an elevated risk for cancer, 40+ or older Detection of early colorectal cancer and precancerous lesions Patients with a positive test result should be referred ...
... Human B-raf Gene V600E Mutation Detection Kit (Fluorescence PCR Method) Cat. No.: - P111H Specification: 20 T /Kit Specimen: paraffin-embedded tissue sections of human non-small cell ...
... use: The Human K-ras Gene Mutation Detection Kit (PCR-Melting Curve Method) uses genomic DNA extracted from tumor paraffin-embedded tissue sections of human non-small cell lung cancer ...
FOB Gold® is a system which comprises a unique “2 in 1” tube for sample collection and a new generation immunological latex reagent for the determination of fecal occult blood. The patented FOB Gold® tube offers a universal ...
Result display time: 10 min
Specificity: 99.6 %
Preview® One Step Fecal Occult Blood Test is a rapid test for the qualitative detection of human occult blood in feces. It is used as an aid in the diagnosis of lower gastrointestinal (GI) bleeding. All ...
Result display time: 15 min
Specificity: 85 %
Sensitivity: 97 %
... gastrointestinal tract. Test kit includes: The ColonView tests come in packs of 30 tests, each including test cassettes and well-equipped Sample Collection ...
Result display time: 15 min
Sample volume: 0.12 ml - 0.15 ml
... polyps, and colorectal cancer. This test is recommended for use in: 1) routine physical examinations or when hospital patients are first admitted, 2) hospital monitoring for GI bleeding in patients, and ...
... patients. Regulatory status - IVD-CDx Mutation variants - 28 Storage Temp - -20°C (+/- 3°C) 4 well-reactions/test (24 tests/kit)
... software Plasma-SeqSensei™ (PSS) CRC RUO Kit allows the highly sensitive and specific detection of mutations in circulating tumour DNA (ctDNA) from plasma of patients with colorectal cancer ...
Sample volume: 0.025 ml
Colorectal cancer (CRC) is one of the most prevalent types of cancer, ranking as the third most common malignancy and the fourth leading cause of cancer deaths worldwide.[1]A ...
Clarithromycin, Quinolone-Resistant and Non-Resistant Helicobacter Pylori Nucleic Acid Amplification Test Kit Predicator of Gastric Cancer This kit is intended ...
Jiangsu Mole Bioscience
Kit allows researchers to detect KRAS and BRAF mutations via real time PCR analysis. It differentiates eight KRAS mutations and one BRAF mutation.
Result display time: 5 min - 15 min
... , polyps, and colorectal cancer. This FOB test is recommended for use in (1) routine physical examinations, (2) monitoring any bleeding in patients, and (3) screening for colorectal cancer ...
Specificity: 90.8 %
Sensitivity: 93.6 %
... TFPI2 methylation in the background of 5 ng human genomic DNA Packing Specifications 24 tests/kit (non-single test/tube) - 48 tests/kit (non-single ...
... maintaining cell balance. 2.AURKA gene amplification can occur in various tumors such as breast cancer/ovarian cancer/colorectal cancer/prostate cancer/cervical cancer/neuroblastoma.
... traditional guaiac-based methods. Increased specificity to lower GI bleeding makes hema-screen SPECIFIC GOLD an ideal tool for colon cancer screening. Reliable Performance Our Innovative Technology ...
This kit is designed for the detection of PIK3CA gene mutations in the DNA of patients with breast cancer, colorectal cancer, and other related conditions. Mutations in the PIK3CA gene ...
RainSure Scientific
... Society of the United States (NCCN) Guidelines for Clinical Practice in Collectable Cancer (V1.2015) clearly states :(1) All patients with metastatic colorectal cancer should be tested ...
Jiangsu MicroDiag Biomedicine Technology Co., Ltd.
KRAS/NRAS Mutations Detection Kit provides reagents to perform assays for 6 tests Technical information Detection of 19 KRAS mutations (exons 2, 3 and 4) and 13 ...
LCM Genect srl
Result display time: 15 min - 20 min
Specificity: 97 % - 99 %
Sensitivity: 97 % - 99 %
This kit is suitable for in vitro qualitative detection of Human hemoglobin (Hb) and Transferrin (Tf) in human stool samples, and used for auxiliary diagnosis of digestive tract bleeding. The fecal occult blood test ...
Sample volume: 1 ml - 2 ml
... Therefore, measuring the amount of hemoglobin in feces is an effective method for the early detection and treatment of colon cancer and other diseases of the lower digestive tract that are accompanied ...
Result display time: 10 min
Specificity: 99.9, 97 %
Sensitivity: 99 %
... Fecal Occult Blood (FOB) Test is a qualitative im- munochromatographic test detecting human hemoglobin (hHb) in human feces for professional use. • The test kit contains ...
Result display time: 120 min
... BRAF gene targeted drugs such as Vemurafenib for melanoma patients, Erbitux (cetuximab) and vectibix (panitumumab) for colorectal cancer patients. Key Features Detection principle: Real-time PCR ...
Result display time: 4 h
... tumors (granulocytoma); 4. Long-term use of females hormones; 5. Genetic factors, family history of colon cancer (lynch syndrome). In 2013,The Cancer Genome Atlas (TCGA) studied 373 ...
SPACEGEN
Result display time: 90 min
... mutation accounts for 80-90% of BRAF mutations. This kit is used for qualitative assay of BRAF V600E point mutation in patients with non-small cell tung cancer (NSCLC), colorectal cancer, ...
Beijing ACCB Biotech Ltd.
Result display time: 10 min
... colorectal cancer. The iFOB Neo test detects the miniscule amount of blood in the stools. Detection of hemoglobin should warrant further examination. Diagnosis diseases Colorectal cancer, ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining