Storage temperature: 2 °C - 8 °C
Conveniently supplied liquid ready-to-use the Liquid HbA1c control is ideally suited to both clinical laboratories and POCT helping to significantly reduce preparation time. With a stability of 30 days waste and costs ...
Randox Laboratories
The RIQAS Sweat Testing EQA programme has been designed to cover the analysis of Sweat Testing in clinical laboratories measuring the concentration of Chloride, Sodium and Conductivity in sweat, used in the testing of ...
Randox Laboratories
Storage temperature: 2 °C - 25 °C
"Dedicated control for use in the routine monitoring of the Randox Total Antioxidant Status assay on clinical chemistry analysers Features & Benefits Lyophilised for enhanced stability Bovine based serum Analytes Total ...
Randox Laboratories
... characteristics of an in vitro diagnostic laboratory test and is an integral part of good laboratory practice. The CanChek controls are available in two levels, in order to provide performance monitoring over the clinical ...
Fujirebio
... marker may be used as an aid in the diagnosis and management of patients with known or suspected gastrointestinal carcinomas4-9. The CanAg Diagnostics CA242 EIA should not be used as a substitute for ...
Fujirebio
... testing procedures for the analysis of pTau 181 in plasma on the automated LUMIPULSE G System. This product is not for use in diagnostic procedures.
Fujirebio
... monitoring of ketosis Diagnostic grade precision, sensitivity, and monitoring tool FDA -Cleared Method Industry Leading Performance Made in the United States The Stanbi Chemistry LiquiColor® Beta-Hydroxybutyrate ...
The BD MAX™ system offers you an efficient path to improved clinical outcomes by combining and automating extraction and thermocycling into a single platform capable of running both FDA-cleared and open system assays. ...
Storage temperature: -20 °C
The digene Specimen Transport Medium is intended for in vitro diagnostic use in Europe. ✓ 24/7 automatic processing of online orders ✓ Knowledgeable and professional Product & Technical Support ✓ Fast and reliable ...
Storage temperature: -25 °C - -15 °C
... into viral infectivity and replication. Suitable for patients undergoing antiviral therapy, results should be evaluated with clinical symptoms and other methods for comprehensive assessment. Not for blood screening. This ...
Xian Tianlong Science and Technology
... procedure. Therefore, T have been innovating and improving as always, and have upgraded our rapid viral DNA/RNA extraction reagents which are now faster, easier, more efficient and more accurate, and better for your ...
Xian Tianlong Science and Technology
Storage temperature: 20 °C - 25 °C
Purity: 99 % - 99.9 %
... The whole operation process is safe, convenient and no need for organic reagent. The extracted nucleic acids are highly purified and can be widely used in the fields of diagnostics, genomics research, ...
Xian Tianlong Science and Technology
Storage temperature: -25 °C - -15 °C
... in the experimental protocol in the context of gene expression studies (housekeeping controls) > Positive controls for diagnostic PCRs. See our IPC (RT-IPCY-xxxx) & SPC (RT-SPCY-xxxx) controls. Universal Exogenous ...
Eurogentec
... primers and probes for in vitro diagnostic procedures for assays based on PCR techniques and it is compatible with manual or automatic systems. The STAT-NAT® DNA Mix kit is intended for professional use only. REAGENT: ...
SENTINEL DIAGNOSTICS
... primers and probes for in vitro diagnostic procedures. For professional use only. The kit consists of 12 strips of 8 RNA mix tubes, each containing one optimized freeze-dried RNA reaction mixture (96 reactions total). REAGENT: ...
SENTINEL DIAGNOSTICS
Direct colorimetric Ferene method without deproteinization on serum and plasma - Ratio: Sample/Reagent 1/Reagent 2: 1/12.5/1 - TWO LIQUID REAGENTS - Wavelength 600 - Linearity 1000 ...
SENTINEL DIAGNOSTICS
Specific Protein Test Menu for Diabetes HbA1c
Goldsite Diagnostics Inc.
Specific Protein Test Menu for Immune Disease IgG IgM IgA C2 C3, KAP, LAM
Goldsite Diagnostics Inc.
Specific Protein Test Menu for Renal mALB AMG RBP BMG Al M Cys C Urine IgG Urine TRF Urine KAP Urine KAP Urine LAM Urine AMG
Goldsite Diagnostics Inc.
Storage temperature: 2 °C - 8 °C
Aspartate aminotransferase (AST/GOT) catalyzes the transfer of the amino group from aspartate to oxoglutarate with the formation of glutamate and oxalacetate. The latter is reduced to malate by malate dehydrogenase (MDH) in the presence ...
LINEAR CHEMICALS
Storage temperature: 2 °C - 8 °C
Bilirubin is converted to coloured azobilirubin by diazotized sulfanilic acid and is measured photometrically. Of the two bilirubin fractions in serum –bilirubin-glucuronide and free bilirubin which is bound to albumin– only the former ...
LINEAR CHEMICALS
Storage temperature: 2 °C - 8 °C
Direct bilirubin (conjugated) reacts with the diazonium salt 2,4-dichlorophenyldiazonium (2,4-DPD) in the presence of sulfamic acid to form azo-bilirubin, this coloured complex can be measured photometrically at 546 nm. Of the two bilirubin ...
LINEAR CHEMICALS
Storage temperature: 2 °C - 8 °C
Ready-to-use Integrated CLIA Reagent Kits Pack Size: 25 tests/kit, 50 tests/kit, 100 tests/kit, 200 tests/kit Test Menu -Fertility: FSH/LH/PRL/β-HCG/E2/PROG/TES -Tumor Markers: AFP/CEA/CA125/CA15-3/CA19-9/tPSA/fPSA/CYFRA21-1 -Cardiac ...
Guangzhou KOFA Biotechnology Co.,Ltd.
The CLIA reagent kit covers tumor markers, cardiac markers, hormones, thyroid function, metabolism, inflammation and other testing series, which can meet different clinical testing needs.
Guangzhou KOFA Biotechnology Co.,Ltd.
Ready-to-use Liquid Clinical Biochemistry Reagent Pack Size: General and bulk package Applicable Biochemistry Analyzer: Hitachi/Beckman AU/Abbott/Roche Cobas/Olympus/Mindray
Guangzhou KOFA Biotechnology Co.,Ltd.
Clinical Chemistry Reagents 1. Lyophilized 2. Liquid Stabe 3. Chemicals 4. System Reagents Immuno Chemistry Reagents 1. SensIT 2. System Reagents ...
... and success: know that the reagents that leave our factory pass a minimum of 3 quality controls before being launched in our different markets. In addition, it is important to note that we validate the quality of our ...
... more pipets. Never wait just open and use. ECONOMICAL No need to prepare a full house of reagent unlike with lyophilized reagents. Open a bottle when you need it, and manage your ...
Determinations of albumin level in serum are mainly used in monitor and aid in the diagnosis of clinical conditions associated with hypoalbuminemia. Decreased albumin levels may be associated with severe ...
Cormay Diagnostics
... and primary biliary cholangitis (PBC). Specification Method Kinetic method recommended by International Federation of Clinical Chemistry (IFCC) Specimen serum, plasma On board stability up to 12 weeks Calibration ...
Cormay Diagnostics
... secreted by salivary and pancreatic glands. Determinations of α-amylase activity in serum and urine are mainly used for the diagnosis and differentiation of pancreatic diseases. Increased levels of the enzyme are observed ...
Cormay Diagnostics
... Draft writer of China National D-Dimer standard “27 YYT 1240-2014, China National Pharmaceutical industry standard of D-Dimer reagent (kit)”. 3.Consists as Hemostasis solution with Succeeder coagulation instrument, ...
... produce anti-CCD IgEs, which, however, do not trigger allergic symptoms and therefore most likely have no clinical relevance. This low clinical significance was thought to be due to low binding affinity ...
For in vitro diagnostic use. The RIDA®QUICK IFX Monitoring Control Set is intended for the use with the corresponding, batch specific kit RIDA®QUICK IFX Monitoring. General information: The RIDA®QUICK IFX Monitoring ...
... playing a crucial role in their development. The challenge of their early detection and precise diagnosis is ever more pressing. Traditional diagnostic methods are often invasive, such as cerebrospinal ...
Storage temperature: -20 °C
The APOE gene on chromosome 19, responsible for coding apolipo-protein E, is genetically linked to both common late-onset familial and sporadic forms of AD. The human APOE gene comprises three alleles: -ε2, -ε3, and -ε4 distributed in ...
... b-hydroxylase deficiency as well. Measurement of 17αOHP is therefore valuable in the initial diagnosis of CAH. Usage Statement FDA cleared for In Vitro Diagnostic (IVD) use in the United States. CE ...
MP Biomedicals
... In Vitro Diagnostic (IVD) use in the United States. CE Marked for IVD use outside the United States. Key Applications Endocrinology Analyte / Target - High Sensitivity C-Reactive Protein (hsCRP) Base Catalog Number ...
MP Biomedicals
... States. Key Applications Endocrinology Analyte / Target - Cortisol Base Catalog Number - M21602 Diagnostic Platforms - EIA/ELISA Diagnostic Solutions - Endocrinology Disease Screened - Cortisol Evaluation ...
MP Biomedicals
Storage temperature: 2 °C - 8 °C
... different lot of reagent and when the instrument is adjusted. REAGENT PREPARATION Reagents are supplied in a two vial, ready to use, liquid form. Swirl the latex vial gently ...
BILIMSEL TIBBI ÜRÜNLER
Storage temperature: 2 °C - 8 °C
... PRECAUTIONS 1. This reagent is for in vitro diagnostic use only. 2. Reagent contains sodium azide. Poison. Do not ingest . REAGENT PREPARATION Reagent ...
BILIMSEL TIBBI ÜRÜNLER
Storage temperature: 2 °C - 25 °C
... This reagent is for in vitro diagnostic use only. 2. Do not pipette by mouth. Avoid contact with skin and clothing. REAGENT PREPARATION The reagent is ready ...
BILIMSEL TIBBI ÜRÜNLER
Storage temperature: -20 °C
Genetically modified thermostable Taq DNA Polymerase that provides robust and reproducible results robust amplification in routine applications suitable for templates up to 5 kb reaction set-up and shipment without ice TA cloning Description FIREPol® ...
Solis BioDyne
Storage temperature: -20 °C
load directly to gel after PCR suitable for templates up to 5 kb reaction set-up and shipment without dry ice all-in-one master mix format reduces pipetting errors and saves time Description Optimized ready-to-use PCR master mix ...
Solis BioDyne
Storage temperature: -20 °C
A chemically modified hot-start version of the thermostable Taq DNA polymerase FIREPol®. This enzyme is activated only by pre-incubation at 95°C, preventing any unspecific polymerase activity at lower temperatures during reaction set-up. increased ...
Solis BioDyne
Storage temperature: 2 °C - 8 °C
Red blood cell (RBC) folate is considered the most reliable indicator of folate status as it reflects tissue stores more closely and is less sensitive to short-term dietary effects. Compared with serum folate, RBC folate can be an indicator ...
Nanjing RealMind Biotech Co., Ltd
Storage temperature: 2 °C - 8 °C
RealMind Cardiac menu has 9 biomarkers, including: hs-cTnI, hs-cTnT, NT-proBNP, BNP, D-Dimer, CK-MB, Myoglobin, Lp-PLA2, ST2. The advantages of RealMind Cardiac menu includes: · All tests support whole blood samples, allwoing shorter ...
Nanjing RealMind Biotech Co., Ltd
Storage temperature: 2 °C - 8 °C
RealMind Inflammation menu includes the following biomarkers: · Procalcitonin (PCT) · IL-6 · IL-8 · IL-10 · IL-1β · IL-2R · TNFα
Nanjing RealMind Biotech Co., Ltd
Storage temperature: 2 °C - 8 °C
Blood screening reagents are GMP certified,quality guaranteed Independent supply of R&D and supply of raw materials 40 years experience in manufacture and quality management Easy Operation: Can be operated ...
Shanghai Kehua Bio-engineering
Storage temperature: 2 °C - 8 °C
Blood screening reagents are GMP certified,quality guaranteed Independent supply of R&D and supply of raw materials 40 years experience in manufacture and quality management Easy Operation: Can be operated ...
Shanghai Kehua Bio-engineering
Storage temperature: 2 °C - 8 °C
... developed and manufactured HBV test kits in 1991. For more than two decades, this series of test kits has been widely used in clinical practice. Being unique in raw material preparation, product design and process, they ...
Shanghai Kehua Bio-engineering
Diabetes glycosylated hemoglobin (HbA1C) Diabetes glycosylated hemoglobin (HbA1C)reagents test kit for Clinical In Vitro Diagnostic closed system analyzer Intended use: Used ...
... the process of cell pellet preparation, suitable for DNA extraction. “MOLgen Hemolytic Solution Kit” can be applied in clinical and research practice. Principle Of Method Operation principle of “MOLgen Hemolytic ...
ADALTIS
... Solution 1 Kit” is intended for transportation and storage of clinical specimens. Introduction “MOLgen Transportation Solution 1 Kit” is intended for transportation and storage of clinical specimens ...
ADALTIS
... Solution 2 Kit” is intended for transportation and storage of clinical specimens. Introduction “MOLgen Transportation Solution 2 Kit” is intended for transportation and storage of clinical specimens ...
ADALTIS
... identification Similar sensitivity to nasopharyngeal samples in molecular assays General information The success of virus diagnosis depends largely on the quality of the specimen and the conditions under which ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining