- Laboratory >
- Immunology >
- ELISA kit
ELISA kits

... visualization of color change upon sample addition to microwells. Kit Configuration and Principle of Test The product is available in three kit configurations, the 384, 960, and 9600 test kits. ...
Avioq

... processed product is used for nucleic acid analysis. Product Description BunnyQuant dsDNA HS Assay Kit is a fluorescent quantification kit for the specific detection of double-stranded DNA (dsDNA). ...
BunnyTeeth Technology Inc.

The Biomerica EPO ELISA is intended for the quantitative determination of Erythropoietin (EPO) in human serum. This assay is intended for in vitro diagnostic use.
BIOMERICA

Result display time: 50 min
Sample volume: 0.01 ml
Specificity: 90 %
CE-marked Enzyme Immunoassay (ELISA) kit for the detection of IgM antibodies to SARS-CoV-2 in human serum. Main Features: Number of tests: 96 Principle: Indirect ELISA using ...

Result display time: 2, 30 h
Sample volume: 0.2 ml
The EPO ELISA is intended for the quantitative determination of Erythropoietin (EPO) in human serum. This assay is intended for in vitro diagnostic use, as an aid in the diagnosis of anemias and polycythemias. With the ...
DRG Instruments GmbH

Manufactured by SafePath® exlusively for Centaur Animal Health, the FP-ELISA II Kit is Centaur’s third generation test for antibodies to Equine Infectious Anemia Virus in horse serum. Its name is derived ...

... serum dilution and sorbent treatment (IgM detection) directly in the well. Suitable for automated ELISA systems General information The ELISA method is based upon the reaction of antibodies in ...

Specificity: 90 %
... has been performed using ELISA assays or on closed mainframe immunoassay analysers. Now for the first time Anti-CCP testing can be performed on open chemistry systems using the new Axis-Shield Clinical Chemistry Anti-CCP ...
Axis-Shield PLC

Result display time: 120 min
... The kit allows 96 tests, including controls in a split microtiter plate with color-coded strips and breakable wells. Advantages: The total assay time is about 2 hours. High sensitivity and specificity ...
TestLine Clinical Diagnostics

... Veterinary reagents Species reactivities of our veterinary assays and included monoclonal antibodies are summarized in the tables below. Symbol keys: Cross-reactivity Verified by Mabtech and/or by others. Tests performed ...
Mabtech

Result display time: 110 min
Sample volume: 0.1 ml
... use only and not to be used in diagnostics procedures. Anti-IgE Receptor (FcɛR1α) Autoantibody ELISA Kit Anti-IgE Receptor (FcɛR1α) Autoantibody ELISA Kit was developed ...
Eagle Biosciences

Result display time: 105 min
• Use of recombinant human thyroid peroxidase (TPO) • Ready-to-use (exception: wash buffer) and barcoded reagents • Quality assured handling in routine laboratories • Incubation at room temperature • Quantitative ...
MEDIPAN GmbH

Result display time: 3 h - 4 h
Sample volume: 0.05 ml
... similar validation testing as Quantikine® ELISA Kits Precise and Specific Mass-calibrated standards for consistent results with every new lot of material Enough reagents for ...
R&D Systems

Tuberculosis Antibody(IgG) Detection Kit (ELISA)

Specificity: 99 %
Sensitivity: 95 %
... Introduction of Brucella Antibody Competitive ELISA Kit The brucella antibody ELISA kit is based on competitive ELISA to measure the amount of brucella ...
Ring Biotechnology Co Ltd.

... cerebrospinal fluid, we provide our traditional immunoenzymatic kits ELISA-VIDITEST and MONO-VIDITEST and the IF-VIDITEST immunofluorescence kit. VIDITEST kits comes ...
VIDIA s.r.o

Result display time: 25 min
Specificity: 100 %
Sensitivity: 97.4 %
... serum of the cat. Product Format: - 1 test-kit contains 96 determinations (12 test strips with 8 determinations each, breakable into individual wells) Product Format: 1 test-kit contains ...

Sample volume: 0.1 ml
... NGAL is inversely proportional to the logarithm of the concentration of mouse NGAL in the fluid phase. Kit Contents: 1 96-well Mouse NGAL ELISA Plate 2 NGAL Reaction Buffer 1 Mouse NGAL Standard 1 ...

Kit Size: - - - - - - 96 Tests Storage: - - - - - - 2-8°C Specimen: - - - - - Serum Minimum Order Quantity: - 10 kits Description: The Biopanda Total IgE Allergen ELISA ...

Sample volume: 0.025 ml
Enzyme immunoassay for the determination of 17a-Hydroxyprogesterone in human serum and plasma (Li-Heparin) Tests - 96 Incubation Time / Conditions - 1 h (RT/shaker), 30 min (RT/dark) Standard Range - 0.1 - 25 ng/ml Sensitivity ...

Neutralizing Antibody test is used to assess the immunity status of the patient against COVID-19. Unlike a general antibody screen, it spesifically detects the neutralising antibodies.

Result display time: 90 min
Specificity: 99.7 %
Sensitivity: 100 %
... of total antibodies against SARS-CoV-2. The OPTI SARS-CoV-2 Total Antibody Test is an enzyme-linked immunosorbent assay (ELISA) that detects total antibodies (IgG, IgM, and IgA) against the receptor binding domain ...

Specificity: 95 %
Sensitivity: 95 %
... subjects are infected with mycobacterium tuberculosis. The ELISPOT technology platform is used to break through the traditional ELISA method, with a specificity and sensitivity rate as high as 95%. The detection is fast ...

Result display time: 90 min
Sample volume: 0.05 ml
... traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way. Test Principle This ELISA kit ...

Result display time: 80 min
ELISA kit for the qualitative detection of IgG antibodies to SARS-CoV-2 virus Characteristic: Number of tests — 96 Expiration date — 12 monthes Storage temperature — +2...+8° С
Equi
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining