Femoral intramedullary nails

47 companies | 137 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
femoral intramedullary nail
femoral intramedullary nail
5601-01 series

Length: 24.4 mm - 420 mm

... consolidation of the fracture and accelerating the patient’s recovery. It was developed to stabilize femur fractures through its insertion into the intramedullary canal, maintaining alignment and facilitating ...

See the other products
Ortobio
femoral intramedullary nail
femoral intramedullary nail
SpectruM

– long and short nails with increased number of locking holes to fix all fragments – most distal hole is 5 mm from the nail tip – in porotic bone condylar screw with nut can be used – color coded short ...

femoral intramedullary nail
femoral intramedullary nail

Length: 220, 180, 200 mm
Proximal diameter: 11, 12, 9, 10 mm
Degree of curvature: 125 °

PFN Intramedullary Nails: These are used in proximal femoral neck fractures, subtrochanteric fractures, and intertrochanteric fractures. The proximal part of the nail ...

See the other products
Otta Medical
femoral intramedullary nail
femoral intramedullary nail
Neon

Length: 220 mm - 420 mm
Proximal diameter: 15.5 mm
Distal diameter: 11 mm

Neon is a titanium nail designed for the treatment of proximal femoral fractures. By using the Claw technology in the distal end and lag screw, this nail allows surgeons to perform at ...

femoral intramedullary nail
femoral intramedullary nail

Length: 200 mm - 420 mm
Proximal diameter: 11.5, 12 mm

... CT & MRI due to the nail. •Advantageous in pathological fractures Screws: Ø5mm * Special Order ** CarboFix nails & plates are supplied sterile *** CarboFix nails & plates ...

See the other products
CarboFix Orthopedics
femoral intramedullary nail
femoral intramedullary nail
869867345 series

Length: 450, 350 mm
Degree of curvature: 150 °

Titanium Elastic Pin is an intramedullary nail system designed to meet the need for flexible, compressible and durable implants with different diameter and length options in cases where the bone medulla ...

See the other products
Peditst
femoral intramedullary nail
femoral intramedullary nail
01021401

Length: 320 mm - 420 mm

... Both nails offer increments of 20 mm between each of their lengths. The end cap protects the proximal nail thread to facilitate its extraction. The solid nail is preferred for use ...

See the other products
Truemed Group
femoral intramedullary nail
femoral intramedullary nail
LNS GT

Length: 150 mm - 480 mm
Degree of curvature: 125, 130 °

... static or dynamic Proximal markings for radiographic reference (5 and 10 mm) to indicate the nail insertion depth LNS GT SHORT NAIL AND LNS-GT STANDARD NAIL from Surgival: The 150 ...

femoral intramedullary nail
femoral intramedullary nail
CHARFIX2

Length: 180 mm - 480 mm
Proximal diameter: 8 mm - 19 mm

is a solution when other treatment method failed. It is made of titanium and its alloys and is used to join femur and tibia at the side of knee resection or partially removed join surface. INDICATIONS: failed ...

See the other products
ChM
femoral intramedullary nail
femoral intramedullary nail
14510-11180

Length: 180 mm - 420 mm
Proximal diameter: 15.5 mm
Distal diameter: 9 mm - 12 mm

... developed for the surgical treatment of trochanteric fractures and of some cases of femoral neck fractures. The system combines the biomechanical advantages of the intramedullary nailing and the traditional ...

See the other products
Medimetal
femoral intramedullary nail
femoral intramedullary nail
ORTOLOCK

See the other products
Ortosintese
femoral intramedullary nail
femoral intramedullary nail

Length: 320 mm - 420 mm
Proximal diameter: 10, 11, 12 mm

Diameter: 10 - 11 - 12 Length: 320 - 340 - 360 - 380 - 400 - 420 Set: 1 Nail - 2 End Cap - 1 Lag Screw - 1 Distal Screw

See the other products
DTM - Deva Tibbi Malzemeler
femoral intramedullary nail
femoral intramedullary nail

... comprehensive approach to the treatment of femoral fractures with its Modular Femoral Nail. The “Mod” Nail allows for multiple surgical femoral nail ...

femoral intramedullary nail
femoral intramedullary nail

Length: 180 mm - 440 mm
Proximal diameter: 9, 10, 11, 12 mm
Degree of curvature: 130 °

Several distal locking options Static or dynamic locking can be performed via the aiming arm with PFNA standard, small and xs. The PFNA long additionally allows for secondary dynamization. Increased stability caused by bone compaction ...

femoral intramedullary nail
femoral intramedullary nail
EBA2

Length: 10 mm - 460 mm
Degree of curvature: 130, 5 °

... indicated for the treatment of stable and unstable intertrochanteric, pertrochanteric and subtrochanteric fractures. EBA2 fémoral nail is designed to allow a controlled sliding of the two cephalic screws ...

See the other products
Citieffe
femoral intramedullary nail
femoral intramedullary nail
TFP

Length: 255, 190 mm
Degree of curvature: 130, 125 °

The TFP nail is intended for the treatment of proximal femur fractures. The TFP product line consists of: – short nails (L. 190mm) available in 130° and 125° versions – long nails ...

femoral intramedullary nail
femoral intramedullary nail
INTERNA® PFN

Length: 180 mm - 480 mm
Proximal diameter: 10 mm - 15 mm
Degree of curvature: 120, 125, 130 °

... short and long proximal intramedullary femur nails (PFN) are cannulated to facilitate insertion control and feature a universal anatomical design. It is indicated for the temporary fixation, ...

femoral intramedullary nail
femoral intramedullary nail

... intercondylar fossa roof. Nails are hollow, have a circular cross-section. Nails of 10,5 mm diameters have a distal part of 35 mm wider to diameter 11,5 mm. Nails of size 12,5 mm have ...

See the other products
MEDIN
femoral intramedullary nail
femoral intramedullary nail

Femoral shaft fractures down to the middle third Combined injuries of the femoral neck and trochanter area and subtrochanteric and shaft injuries Pathological fractures – in the case of single or multiple ...

femoral intramedullary nail
femoral intramedullary nail
VITUS-PF

VITUS-PF Proximal Femoral Nail ø 17mm, long Indication: - low and extensive subtrochanteric fractures, - combined fractures of the trochanteric area and the femoral shaft - pathological fractures

femoral intramedullary nail
femoral intramedullary nail
EVO-NAIL PLUS

Degree of curvature: 4 °

The Evo-Nail PLUS is a nail that allows the surgeon to treat a wide spectrum of femoral fractures, offering advantages such as a simplified surgical procedure and different surgical options. The ...

See the other products
Gruppo Bioimpianti
femoral intramedullary nail
femoral intramedullary nail
PediFIN®

Length: 140 mm

The Pediatric Proximal Femoral Nail, PediFIN® centers on general intramedullary nailing principles and reshaping for pediatric use. The nail is designed specifically ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us
MedicalExpo RFQ: Free quotation comparison tool
Receive and compare quotations for free
Describe your project
We select
the best suppliers
Compare quotations and complete your purchase