Trauma System plates and screws are intended to be used for internal bone fixation for bone fractures, fusions, osteotomies and non-unions appropriate for the size and design of the device. The large plate ...

Length: 56, 184 mm
Thickness: 2.3 mm
Hole diameter: 2.7, 3.5 mm
... reinforced polymer. •Polyaxial locking screws - up to 10° trajectory variation. •Circumference radiopaque marking outlining plate contour for positioning & follow-up. Features •Radiolucent: Superior fracture imaging. •Unparalleled ...

... LOCK Distal Fibula Plates are indicated for fractures, osteotomies and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone. 5 hole ...
Truemed Medical

Aplus distal Fibula Double Hook plate was designed based on the Asian bone database. The plate fits better with Asians, making it suitable for various types of lateral malleolus fractures. FEATURES 1.Low-profile ...

Length: 82, 107, 132 mm
... Anatomically pre-shaped plates reduce soft tissue irritation and do not require additional modelling. • Diaphyseal and metaphyseal fractures of the distal fibula (4F3). • Intra and extra articular ...
Intrauma

Hole diameter: 1.6, 2.7 mm
Number of holes: 5, 12 unit
► 1/3 Semi tubular Locking Plate ► Self-tapping Cortex Screw ► Cancellous Screw ► In both ends of the plate holes for 01.6 mm Kirschner wires

... in various lengths and number of holes for each type of plate. The use of cortical screws, self-tapping cortical screws and cancellous bone screws in different sizes are recommended for each plate model.

Length: 85, 145 mm
Number of holes: 4, 10 unit
... • Insertion of the plate and its positioning. • Temporary stabilization of the implant using Kirschner wires. • Introduction of the screws in the distal parts of the plate. • Stabilization of the shaft ...
ChM

Length: 3.5, 2.7 mm
3.5mm Distal Fibula Locking Plate (I) 3.5mm Distal Fibula Locking Plate (II) 2.7 / 3.5mm Distal Posterolateral Fibula Locking Plate 2.7/3.5mm ...

Length: 102, 126, 150, 54, 78 mm
Thickness: 1.5 mm
Number of holes: 4, 6, 8, 10, 12 unit
This plate is indicated for fractures of ulna, radius and fibula shaft. Low Plate profile and rounded plate edges minimize tendon and soft tissue irritation
DTM - Deva Tibbi Malzemeler

- Optimal Fit - Screw Trajectory - Fully Instrumented System - Pre-contoured Plates - Thin profile towards the joint line

... the ankle joint. The plates are designed to be used with both locking and non-locking screws although locking screws provide stronger and more stable fixation. All the plates have compression ...

Anatomically pre-formed plate design for right and left leg Rounded edges and flattened plate head minimize the soft tissue irritation High primary stability thanks to Ø 3.0 mm and Ø 3.5 mm locking ...
Intercus

Indikation: As tension band, neutralization or buttress plate in fibula, distal ulna, olecranon and metatarsus.

... holes allowing reduction and stabilization of the Wagstaff fragment/AITFL to the plate • Anatomic medial malleolar plate o Patent-pending design (US29/719,840) o Specifically designed to allow buttress ...

Length: 64, 87, 98.5, 121, 199.7 mm
Thickness: 1.6 mm
Number of holes: 2, 4, 5, 7, 13 unit
... ankle joint. The plates are designed to be used with both locking and non-locking screws although locking screws provide stronger and more stable fixation. All the plates have compression ...
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining