Face velocity: 0.3 m/s - 0.8 m/s
Power: 700, 400, 500 W
Depth: 800 mm
... workshop and clean workshop. Widely used in electronics, chemical, machinery, universities, laboratories and other fields. The fume hood can be used for the operation of potentially dangerous or unknown ...
Face velocity: 0.3 m/s - 0.8 m/s
Power: 400, 500 W
Depth: 840 mm
Fume Hood is a kind of negative pressure ventilation system for protecting operator and laboratory environment. Room air flows inward from the front opening of the Fume Hood and is consistently ...
Face velocity: 0.4 m/s - 0.6 m/s
Power: 400, 500 W
Depth: 830, 940 mm
... be generated during the experiment. To protect the safety of users and prevent the spread of pollutants in laboratories, fume hoods are used. Features: 1. LCD touch screen control panel, easy to ...
Length: 48, 60, 96, 24, 36 in
Depth: 29, 35.5 in
Height: 22.8, 32 in
Protector XVS Ventilation Stations may be used as light duty fume hoods, science classroom work stations, solvent cleaning work bays, weighing stations or for pathology and cytology. With glass tops and ...
Labconco
Depth: 640 mm
Height: 1,350, 900 mm
... for limited laboratory spaces or pharmacies: The pharmacy fume cupboard adapts flexibly to the space conditions. Specially developed for handling hazardous substances in pharmacies, pharmacy fume cupboards ...
... regulation in force). 6/7 mm accident prevention stratified frontal glass with electric vertical slide to contain toxic fumes inside the hood (in compliance with the regulation in force).
Face velocity: 0.3 m/s - 0.8 m/s
Power: 400, 500 W
Length: 1,000, 1,220, 1,525, 1,830 mm
... controller with LCD display FMH series fume hood is a kind of negative pressure ventilation system for protecting operator and laboratory, utilizes carbon filtration to protect laboratory personnel ...
... prevent the leakage of contaminated liquids. The hood is closed at the front part by an acrylic glass slide rail which runs between the polizene lateral guides. The tool rack panel is on the hood ...
Comecer
... compartment (perpendicular to it). Furthermore, it can be used as a passage for the radioactive fluids with a connection from the floor by means of a lead duct, with 30 mm thickness (optional, upon customers request).
Comecer
Radiochemistry shielded hood for manipulations at medium activity, with frontal sliding shield and laminar flow. Workstation suitable for the breakdown of the air-hanging radio-isotopes coming from the manipulation of ...
Comecer
Power: 400 W
Length: 1,200, 1,500, 1,800 mm
The Fume Hood (with Pipes) is the primary barrier in the chemistry laboratory that protects experimenters from hazardous chemical fumes, a high-efficiency safety device for suppression ...
Depth: 778, 777 mm
Height: 2,350 mm
The NU-620 employs a “piston of air” design that is configurable with dual-sided access for workflows needing flexibility in tight spaces. Overview The AllerGard NU-620 Dual Access Animal Transfer Station (ATS) employs a “push-pull” ...
Power: 750 W
Depth: 900 mm
Height: 2,470 mm
... MANAGEMENT We offer complete Project Management from initial enquiry to installation and solution support. Filtration Fume Cupboards can be installed anywhere within your workspace. Our advanced filtration technology, ...
... consequence, Saratoga has developed a range of extractor hoods with a number of options: electric or gas plates and ovens, soldering bottles and etching drawers. EXTRACTOR HOODS Oven hoods ...
Power: 450 W
Depth: 795 mm
Height: 1,075 mm
... solution is undoubtedly to use laminar flow equipment. The benefits of the range Savings Olis horizontal laminar flow hoods offer energy savings thanks to low-energy LED lighting. Safety Olis biological enclosures ...
Erlab
Power: 500 W
Depth: 795 mm
Height: 1,075 mm
... solution is undoubtedly to use laminar flow equipment. The benefits of the range Savings Olis horizontal laminar flow hoods offer energy savings thanks to low-energy LED lighting. Safety Olis biological enclosures ...
Erlab
Power: 650 W
Depth: 795 mm
Height: 1,075 mm
... solution is undoubtedly to use laminar flow equipment. The benefits of the range Savings Olis horizontal laminar flow hoods offer energy savings thanks to low-energy LED lighting. Safety Olis biological enclosures ...
Erlab
The laboratory uses chemicals generating harmful gases, odors and fumes that hinder the work environment and are bad for health, but the PURIFUME is essential equipment to maintain a pleasant laboratory work environment ...
Specially designed to extract combustion fumes and flame vapours. Can also be used in graphite furnaces for atomic absorption instruments to prevent the atoms from spreading into the general laboratory environment. Designed ...
Power: 700, 900, 1,400 W
Length: 945, 1,250, 1,555, 1,860 mm
Depth: 925 mm
The Helios range of hoods is Horizontal laminar flow hoods. They are used in all situations where the product needs to be protected from harmful effects due to the uncontrolled spread of airborne contaminants ...
Face velocity: 0.4 m/s
Power: 760 W
Depth: 790 mm
Designed for those applications with non-hazardous materials, in a particle-free environment for complete product protection. Products handled include non-pathogenic biological samples, cell and tissue cultures, in the pharmaceutical, ...
Face velocity: 0.3 m/s
Depth: 1,000 mm
Height: 1,603 mm
... Mining (EFA-M) is a ducted fume hood designed specifically for users in the mining industry. It has a 100mm deeper workzone to help contain chemical splashes and spills from highly corrosive chemicals. Each ...
ESCO
Power: 92 W
... surface depth under 800 mm Available in different widths (900 mm, 1200 mm, 1500 mm or 1800 mm) Ability to work in standing or sitting position Service access in the front Option: UV light for decontamination ...
Depth: 820 mm
Height: 1,960 mm
„SychemWASTE“ is a plug-and-play disposal unit with a spacious work area – ideal for handling small and large cages. It comes standard with pre-filters and HEPA filters for a quiet exhaust air to remove dust and potential allergens. ...
Depth: 700 mm
Height: 2,200 mm
Fume hood laboratory SW-1 is designed for conducting experiments and tests in laboratories that require a reliable protection of personnel from harmful substances. The transparent glass allows you to ...
Depth: 700 mm
Height: 2,200 mm
Fume hood laboratory SWISS-2 is designed for chemical and physical analyses of the hazardous substances, emit vapors, cabinets are used in laboratories for various purposes. The transparent glass allows ...
Length: 957, 1,262, 1,567, 1,872 mm
Depth: 765 mm
Height: 1,370 mm
The BCS is an EXHAUST FUME HOOD made of COPLAST (expanded PVC) The BCS ensures the protection of the manipulator and his environment thanks to a depression of the working volume towards the outside. Designed ...
The all-stainless steel GLOBO Series hoods come in two versions: closed with sliding glass door or wall mounted. Both models are fitted with a low-noise and powerful 801 m3/h induction extractor fan and LED lighting. The ...
Power: 100 W
Depth: 88 cm
Height: 225 cm
Fan Suction Capacity - 1750 m3 / hr Siding Cabin Glass - Laminated Safety Glass 6 mm Gas & Water Valves - Available Gas & Water Nozzles - Available Electricity Outlet - 2 pcs Working Cabin Dimension - 118 x 90 x 75 cm ( W x H x ...
Elektro-mag
Power: 100 W
Depth: 88 cm
Height: 152 cm
Fan Suction Capacity - 1750 m3 / hr Siding Cabin Glass - Laminated Safety Glass 6 mm Gas & Water Valves - Available Gas & Water Nozzles - Available Electricity Outlet - 2 pcs Working Cabin Dimension - 118 x 90 x 75 cm ( W x H x ...
Elektro-mag
Power: 100 W
Depth: 88 cm
Height: 225 cm
Fan Suction Capacity - 1750 m3 / hr Siding Cabin Glass - Laminated Safety Glass 6 mm Gas & Water Valves - Available Gas & Water Nozzles - Available Electricity Outlet - 2 pcs Working Cabin Dimension - 118 x 90 x 75 cm ( W x H x ...
Elektro-mag
Face velocity: 0.4 m/s - 0.6 m/s
Power: 250 W
Length: 750, 900, 1,200, 1,500, 1,800 mm
Topair’s Polypropylene Ductless Fume Hood – PRO with EN and ASHRAE certification provides a safe work environment for lab staff working with acids and harsh chemicals. The hood includes ...
TopAir Systems, Inc.
Length: 1,020 mm
Depth: 621 mm
Height: 1,920 mm
Fume hood SHV-1,0-“Laminar-S.” is designed for use in laboratories providing operator’s protection when working with chemically harmful materials and for their effective removal. Application of the ...
LAMSYSTEMS
Depth: 695, 724, 686 mm
Height: 2,210, 1,778, 1,981 mm
... leakage Low airflow alarm warns of unsafe conditions Compliant with ANSI, OSHA, AFNOR and BSI safety standards Portable fume hood with transparent front, back and side walls for maximum visibility. ...
Air Science
Face velocity: 0.3 m/s - 0.5 m/s
These fume hoods are designed to meet the needs of teachers and students by providing the greatest visibility, allowing an instructor to spot any hazardous situations that may occur. Observation2™ fume hoods ...
Mott Manufacturing
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining