- Laboratory >
- Laboratory infrastructure >
- Laboratory microbiological safety cabinet
Laboratory microbiological safety cabinets
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/299012-17861187.jpg)
External width: 1,340 mm
External depth: 850 mm
External height: 2,160 mm
Professional air purification equipment suitable for pharmaceuticals, medical and health industries, scientific research laboratories of universities and colleges as well as other related fields. Platform Arm Rest Platform ...
Haier Biomedical
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/299012-18025579.jpg)
Air inflow rate: min 0.53 m³/s
Air downflow rate: min 0.3 m³/s
Sound level: 65 dB
... single person operations, such as virus sampling warehouses, sampling stations at airports and railway stations, on-board laboratories, and other space limited organizations.
Haier Biomedical
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/299012-17861406.jpg)
External width: 1,636, 1,336, 1,936 mm
External depth: 790 mm
External height: 2,120 mm
The X series of standard Class II microbiological safety cabinets are suitable for basic cell biology, microbiology, biomedicine, biosafety laboratories and other laboratories. ...
Haier Biomedical
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84845-20045320.jpg)
Air inflow rate: 348 m³/h - 462 m³/h
Air downflow rate: 649 m³/h - 863 m³/h
Exhaust flow rate: 348 m³/h - 462 m³/h
The EN Class II A2 Biosafety Cabinet is a crucial piece of laboratory equipment designed to provide a safe working environment when handling biological materials that pose a moderate ...
Biobase
![type A2 biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84845-20045388.jpg)
Filtration efficiency: 100 %
Air inflow rate: 0.53 l/s
Air downflow rate: 0.33 l/s
Biological safety cabinet is necessary equipment in the laboratory in the search of microbiology, biomedical, DNA recombinant, animal experiment and biological products, ...
Biobase
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84845-18803461.jpg)
Filtration efficiency: 100 %
Air inflow rate: 230 m³/h
Air downflow rate: 428 m³/h
... most basic safety protection equipment in the first-level protective barrier of laboratory biosafety. Features: 1. 7-inch large touch color display: touch operation, real-time and clearer display ...
Biobase
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/78678-16475511.jpg)
Filtration efficiency: 100 %
Exhaust volume: 15 l
Window opening: 20.3, 25.4 cm
... Scientific™ 1300 Series Class II, Type A2 Biological Safety Cabinet. Package includes a cabinet with factory-installed UV light, manual adjustable height stand and one set of armrests. ...
![class II biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/301335-20346636.jpg)
Sound level: 67 dB
External width: 740 mm
External depth: 650 mm
... Equipped with height limit alarm device Front window and germicidal lamp interlocking design Biological safety cabinet is necessary equipment in the laboratory in ...
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/86445-19887024.jpg)
Air inflow rate: 770 m³/h
External width: 1,025, 1,215 mm
External depth: 780, 820 mm
... offer low-energy lighting for energy savings. Safety Equipped with HEPA H14 filters on the supply and extract sides, dual ventilation with EC motors and a powerful air barrier, the Solis safety cabinet ...
Erlab
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/86445-20347148.jpg)
Air inflow rate: 1,000 m³/h
External width: 1,330, 1,520 mm
External depth: 780, 820 mm
... offer low-energy lighting for energy savings. Safety Equipped with HEPA H14 filters on the supply and extract sides, dual ventilation with EC motors and a powerful air barrier, the Solis safety cabinet ...
Erlab
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/86445-20347202.jpg)
Air inflow rate: 1,240 m³/h
External width: 1,635, 1,825 mm
External depth: 780, 820 mm
... offer low-energy lighting for energy savings. Safety Equipped with HEPA H14 filters on the supply and extract sides, dual ventilation with EC motors and a powerful air barrier, the Solis safety cabinet ...
Erlab
![type B1 microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/80404-16061733.jpg)
Filtration efficiency: 99.99 %
Window opening: 407 mm
Sound level: 63 dB
... II Type B1 cabinet’s traditional role of serving as an intermediate option between recirculating and total exhaust cabinets but gives this design a state-of-the-art control system. Overview The NU-427 ...
NuAire Laboratory Equipment
![type A2 biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/80404-16985478.jpg)
Filtration efficiency: 99.99 %
Window opening: 533 mm
Sound level: 63 dB
... illuminates the procedure inside the cabinet while a dished work tray traps liquid spills and a cord-pass through in the side wall facilitates the use of small electrical devices in the work area. Users easily monitor ...
NuAire Laboratory Equipment
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/80404-16985487.jpg)
Window opening: 533 mm
Sound level: 63 dB
External width: 1,057, 1,362, 1,669, 1,972 mm
... and alphanumeric display for laboratories requiring a clear measurement of their cabinet’s performance and a choice of three NSF listed work access openings for procedures needing ergonomic access to ...
NuAire Laboratory Equipment
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/110835-20065390.jpg)
... lamp. The high purity level of the air, GMP grade A, guarantees the product sterility. Safety had been considered as the primary factor in the design of this cabinet. Consistent with this, an alarm ...
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84663-17482835.jpg)
Filtration efficiency: 99.97 %
Air inflow rate: 612 m³/h
Air downflow rate: 759 m³/h
... sterilisation functionality. Class II Microbiological Safety Cabinets utilise a flow of air drawn via the front aperture into the cabinet. This inward airflow (personnel ...
Monmouth Scientific
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84663-17482879.jpg)
Filtration efficiency: 99.97 %
Air inflow rate: 390 m³/h
Air downflow rate: 492 m³/h
... sterilisation functionality. Class II Microbiological Safety Cabinets utilise a flow of air drawn via the front aperture into the cabinet. This inward airflow (personnel ...
Monmouth Scientific
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84663-17482869.jpg)
Filtration efficiency: 99.97 %
Air inflow rate: 945 m³/h
Air downflow rate: 1,158 m³/h
... sterilisation functionality. Class II Microbiological Safety Cabinets utilise a flow of air drawn via the front aperture into the cabinet. This inward airflow (personnel ...
Monmouth Scientific
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/105953-17027795.jpg)
... ll type A2 biological safety cabinet that protects the user and lab environment from the biohazard factor and prevents cross contamination of various samples used in experiments. Suitable ...
![type A2 biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/105953-17027739.jpg)
... type A2 biological safety cabinet that protects the user and lab environment from the biohazard factor and prevents cross contamination of various samples used in experiments. - Suitable ...
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/69536-18381146.jpg)
... record of safety, reliability and performance, HFsafe LC cabinets make ideal investments for a wide range of applications including work with infectious agents that require Biosafety Level 1, 2 or 3 ...
Heal Force
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/123659-18593152.jpg)
The SafeFAST Classic microbiological safety cabinet is designed and manufactured in such a way that it meets the requirements of the European standard EN 12469: 2000 and offers the highest ...
CARLO ERBA Reagents
![class II biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/89669-9159083.jpg)
Dual Configuration Microbiological Safety Cabinet and Cage Change – surface width: 120 cm - 48” Guaranteed protection for your staff and animals: certified by TÜV-Nord, meets the ...
Tecniplast
![class I biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/112390-10091715.jpg)
Filtration efficiency: 99.99 %
External width: 340 mm
External height: 1,075 mm
... positioning in your laboratory. The Atlas series are class 1 compact safety cabinets and thus providing operator and environment protection for the safe handling and working with ...
LaboGene
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/84923-18147341.jpg)
Sound level: 49, 41, 42.5, 47 dB
External width: 1,045, 1,350, 1,655, 1,960 mm
External depth: 855 mm
The series of Class II microbiological safety extractor hoods are designed and manufactured according to the performance requirements of EN12469: 2000 and are used in all situations where it is necessary ...
Angelantoni Life Science
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/69565-16224994.jpg)
Filtration efficiency: 100 %
Sound level: 60 dB
External width: 1,060, 1,360 mm
Ensuring first class protection for operator, environment and product, MN Series Class II Microbiological Safety Cabinets are the instrument of choice when handling hazardous microorganisms ...
![class III biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/75366-18298366.jpg)
Filtration efficiency: 100 %
Air inflow rate: 0.04 m³/s
Exhaust volume: 4.87 m³
... more productive with the VIVA® Bedding Disposal Animal Workstation (VBD). Specifically designed for the animal research laboratory, the mobile workstation protects personnel and the lab environment from exposure to allergens ...
ESCO
![class II biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/4578538-18121218.jpg)
Safe and fast handling Class II (EN12469) Laminar Flow Air barrier and exhaust ducts Inclined motorized front panel Cytotoxic possibility (CMR)
![class II biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/4581299-19319386.jpg)
![Eurobioconcept](https://img.medicalexpo.com/images_me/logo-pp/L4581299.gif)
class II biosafety cabinetInnosafe®
Innosafe® Class II Biosafety Cabinet allows Class II and III microorganisms handling, for microbiology, virology, hematology, cell culture, genetics. It protects the operator, the product and the environment. ISO5 ...
![class III biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/4581299-19319768.jpg)
Innosafe® Biosafety Class III Cabinet garantees protection for operators and the environnement when handling infectious aerosols and biological agents of level 1, 2, 3, or 4. It is designed to comply with the latests ...
![type A2 biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/299686-17521650.jpg)
Filtration efficiency: 100 %
Air inflow rate: 0.53 m³/h
Air downflow rate: max 0.32 m³/s
... temperature inside cabinet, fan rotation rate, service life countdown for filter, and TVOC concentration probes for both filter outlet and indoor air. 2.This product serves for chemical storage and involves laboratory ...
Alphavita
![class II biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/4581254-19688406.jpg)
External width: 90, 120 mm
... equipped with a lead glass working shield that slides laterally. Features Hood equipment: ⦁ A class II Bio Safety Cabinet BSC ⦁ Lighting of the work surface by LED and UV germicidal ...
ADS Laminaire
![sampling biological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/4581254-19283209.jpg)
External width: 925, 1,250, 1,840 mm
External depth: 911 mm
External height: 813 mm
... BENEFITS Total opening ECM regulation Economical solution Stainless steel worktop Negative pressure safety hoods protect the handler and its surrounding environment from any air contamination, thanks ...
ADS Laminaire
![class II biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/4581254-19283487.jpg)
![ADS Laminaire](https://img.medicalexpo.com/images_me/logo-pp/L4581254.gif)
class II biosafety cabinetPROTEC II
External width: 971, 1,276, 1,581, 1,886 mm
External depth: 786 mm
External height: 1,400 mm
... twin brother of our OPTIMALE model, and complies with the European standard EN 12469, which guarantees the highest level of safety and protection. WHY IS IT IMPORTANT TO USE A WEIGHING STATION WHEN WORKING WITH POWDERS? Working ...
ADS Laminaire
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/128495-17514585.jpg)
External width: 795 mm
External depth: 1,380, 1,990 mm
External height: 1,450 mm
Including premium features in an entry level priced cabinet, the SafeMate EZ series allow everybody to stay safe in an easy way. SPECIFICATIONS V-shaped anti obstruction front grill Electrically operated front glass Tight ...
BioAir
![type A2 microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/121513-13076827.jpg)
Cruma BIO cabinets for microbiological safety and environmental protection are certified by Tüv Nord pursuant to Standard EN 12469:2000. These are CLASS II TYPE A2 cabinets ...
Cruma - Diantech Solutions S.L.
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/112399-16425223.jpg)
Non-compromising safety Kojair always puts safety first, we never take risks by minimizing the flows. All the flows in the cabinet are set to levels, ensuring the safety ...
Kojair Tech Oy
![class II microbiological safety cabinet](https://img.medicalexpo.com/images_me/photo-m2/79006-18070003.jpg)
... special safety measures. Medical, pharmaceutical, genetics and microbiology laboratories therefore use safety workbenches. These protect personnel and the environment while ensuring the ...
Weiss Technik
![class I biosafety cabinet](https://img.medicalexpo.com/images_me/photo-m2/119240-20271190.jpg)
Sound level: 60 dB
External width: 550 mm
External depth: 395 mm
... protection Energy-efficient, highly effective, and operates with minimal noise Applications Biosafety Cabinet Class I is widely used in various laboratory settings for handling low- ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Nuaire laboratory microbiological safety cabinets
- Erlab laboratory microbiological safety cabinets
- Biobase laboratory microbiological safety cabinets
- Haier Biomedical laboratory microbiological safety cabinets
- Nuaire microbiological safety cabinets
- Erlab microbiological safety cabinets
- Biobase microbiological safety cabinets
- Haier Biomedical microbiological safety cabinets
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining