Nominal anode input voltage: 1,320 W - 4,900 W
Nominal tube voltage: 40 kV
The M-113R is a 3.0” (77 mm) 222 kJ (300 kHU) maximum anode heat content.The insert features a 10° and 16° biangular molybdenum alloy target and is available with the following nominal focal spots values: 0.1 (10°) - 0.3 (16°) IEC 60336 This ...
VAREX Imaging
Nominal anode input voltage: 2,500 W - 9,900 W
Nominal tube voltage: 49 kV
The M-113T is a 3.0” (77 mm), 222 kJ (300 kHU) maximum anode heat content. The insert features a 10° and 16° biangular rhenium tungsten molybdenum target and is available with the following nominal focal spots: 0.1 (10°) - 0.3 (16°) IEC 60336
VAREX Imaging
Nominal tube voltage: 42 kV
MED0421 tube is a medium-sized multi-beam X-ray tube developed by NuRay for medical tomosynthesis applications. The designed maximum anode voltage is 42kV, and the maximum ...
Nominal anode input voltage: 0 W - 500 W
Nominal tube voltage: 40 kV
• Metal center section • Molibdenum doped target • Reduced thermal stress on the bearings improves tube life duration • Severe tests during conditioning assure best performance Specifications Anode angle and diameter ...
IAE
Nominal anode input voltage: 0 W - 500 W
Nominal tube voltage: 40 kV
• Metal center section • Molibdenum doped target • Reduced thermal stress on the bearings improves tube life duration • Severe tests during conditioning assure best performance Specifications Anode angle and diameter ...
IAE
Nominal anode input voltage: 0 W - 715 W
Nominal tube voltage: 40 kV
Rotating anode mammography X-ray tube with special bi-angled target, for optimal performances with all techniques. Replaces VARIAN M113SP and M113. Characteristics • ...
IAE
Nominal anode input voltage: 0 W - 715 W
Nominal tube voltage: 49 kV
• Metal center section • RTM target • Reduced thermal stress on the bearings improves tube life duration • Severe tests during conditioning assure best performance Specifications Anode angle and diameter 12.5° ...
IAE
Nominal anode input voltage: 0 W - 715 W
Nominal tube voltage: 49 kV
• Metal center section • RTM target • Reduced thermal stress on the bearings improves tube life duration • Severe tests during conditioning assure best performances Specifications Anode angle and diameter 15° ...
IAE
Nominal anode input voltage: 0 W - 715 W
Nominal tube voltage: 40 kV
Rotating anode mammography X-ray tube with special bi-angled target for optimal performances with all techniques. Characteristics • Two separate focal tracks, small ...
IAE
Nominal anode input voltage: 0 W - 1,000 W
Nominal tube voltage: 40 kV
• Metal center section • RTM target • Reduced thermal stress on the bearings improves tube life duration • Severe tests during conditioning assure best performances Specifications Anode angle and diameter 15° ...
IAE
Nominal anode input voltage: 0 W - 80 W
Nominal tube voltage: 49 kV
... version Specifications Overall length 340 mm Maximum diameter 140 mm Tube assembly net weight 13 kg Maximum tube assembly heat content 375 kJ (500 kHU) Min. tube assembly ...
IAE
Nominal anode input voltage: 0 W - 800 W
Nominal tube voltage: 49 kV
... conventional mammography tube units. • For thermal protection there is a bimetallic thermal switch internally assembled series connected with stator common cable Specifications Overall length 340 ...
IAE
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining