- Laboratory >
- Hematology >
- Mechanical coagulation analyzer
Mechanical coagulation analyzers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... Product Detail Analyzer Introduction Fully Automated Coagulation analyzer SF-9200 can be used for clinical test and pre-operative screening. Hospitals and medical scientific researchers ...
Beijing Succeeder Technology Inc.
Number of reagent positions: 42 unit
... results. 5. Cap-piercing optional. Fully automated coagulation analyzer SF-8200 adopts clotting and immunoturbidimetry, chromogenic method to test the clotting of plasma. The instrument shows that ...
Beijing Succeeder Technology Inc.
... Viscosity based (Mechanical clotting) assay, immunoturbidimetric assay, chromogenic assay. 3. External barcode and printer (not provided), LIS support. 4. Original reagents, cuvettes and solution for better results. Product ...
Beijing Succeeder Technology Inc.
The STA R Max 3 is a versatile analyser that will adapt to any type of laboratory set-up, for an equivalent performance whether used alone or integrated into an automated track. It is supported by a range of reagents ...
Stago
... automating sample integrity checks, the STA Compact Max® 3 makes optimum use of patient samples. Stago employs a unique, mechanical viscosity-based detection system in all its systems offering a reliable-result guarantee, ...
Stago
... interface making it the ideal solution for Hemostasis testing in low-volume labs. The STA Satellite Max is a Hemostasis analyser designed specifically for “satellite” labs looking for a device that meets their needs ...
Stago
Throughput: 30 p/h
Sample volume: 0.05 ml
Number of reagent positions: 1 unit
... only little manual intervention, is easy to perform and ensures consistent, high quality results so you can focus further on standardisation in your lab. Technical specifications Detection principle turbo-densitometric, ...
Throughput: 60, 30 p/h
Weight: 3.8 kg
Width: 200 mm
The BFT II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique turbodensitometric detection device. The semi-automated, dual-channel coagulometer ...
Number of reagent positions: 2, 4 unit
Weight: 2.2, 5 kg
Length: 305, 325 mm
... designed as open systems which can be used with BE reagents and almost all coagulation reagents available on the market. Is a semi-automated opto-mechanical in vitro coagulation analyzer ...
Behnk Elektronik
... features in a flexible, easy to use system. Destiny Max™ is the only instrument offering the choice of optical or micro-mechanical clot detection with reliable cap piercing and result standardisation. The operational ...
Tcoag
Throughput: 320 p/h
Number of sample positions: 40 unit
Number of reagent positions: 20 unit
... result. The present blood coagulation analyzer have TWO detection mode: 1, Optical coagulation analysis technic---low cost, but uncertainty at special samples like jaundice, lipid ...
Shenzhen Thistory Bio-Medical Co., Ltd
Number of sample positions: 16 unit
Reagent volume: 0.05 ml - 0.1 ml
Number of reagent positions: 2 unit
Technical Specifications: Test Menu: PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), TT (Thrombin Time), FBG (Fibrinogen Concentration), Clotting Factors Clotting ...
Number of sample positions: 32 unit
Reagent volume: 0.05 ml - 0.1 ml
Number of reagent positions: 4 unit
Technical Specifications: Test Menu: PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), TT (Thrombin Time), FBG (Fibrinogen Concentration), Clotting Factors Clotting ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining