- Secondary care >
- Orthopedic surgery >
- Primary hip prosthesis
Primary hip prostheses
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... State of Arthroplasty The Metha Short Hip Stem prosthesis represents a new generation of implants for hip endoprosthesis. It combines two advantages: minimal stem size and a circumferential ...
Aesculap®
... distally slim implant design and the standardized implantation technique allow the implant to be used in different femoral anatomies with or without bone cement – with standard or high offset – suitable ...
Aesculap®
... protection of the existing bone substance. Based on the simple but crucial fact that the success of the prosthesis fixation depends on both – implant and bone. To do this, instruments were developed that ...
Aesculap®
Biological Hip Prosthesis System The product design is based on human engineering mechanics, human biology and long-term clinical pathology research. It is made of materials recognized in the world's ...
Waston medical
ALPINE® HIP STEMS The Alpine® Hip System is designed with optimal refinements to the best clinically proven technologies in the market. The stems are offered in cemented and cementless options with common ...
Waston medical
ENTRADA® HIP STEM The Entrada Hip Stem integrates a wealth of clinical history—hydroxyapatite coating, compaction broaching, taper wedge geometry—and provides critical refinements—progressive neck lengths, ...
Waston medical
The MALUCTM Total Hip Arthroplasty System (THA) is used for primary total hip replacement in skeletally mature individuals. modular CoCr and BIOLOX® delta femoral heads in various ...
Femoral stem length: 7.5, 13.5 mm
Femoral Stem Dual Coated (Cementless) SIZE (mm) 7.5 9 10 11 12 13.5
Zimed Medical
Zimed Medical
Calcar Replacement Stem Dual Coated (Cementless) (CoCrMo Alloy) REF. NO SIZE (mm) 7033-3251 25/9 7033-3252 25/11 7033-3253 25/13 7033-3351 ...
Zimed Medical
Titanium total hip prosthesis Medium necks BM0 BM1 BM2 BM3 BM4 BM5 Long necks BM0 BM1 BM2 BM3 BM4 BM5
Custom-made stems from scanner sections Hip prostheses adapted to people of small stature
Hip prosthesis for bone tumor Hip arthroplasty in Pediatric Patient with Cerebral Palsy Pediatric custom made total hip prosthesis
... range of motion than circular neck designs,* which may reduce the potential risk of dislocation. The ANTHOLOGY AFIT Primary Hip System features a reduced distal cross-section as an option for patients ...
CCD angle: 135 °
... approaches to total hip arthroplasty. The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, which facilitates ...
Enovis Surgical
Femoral stem offset: 36, 54 mm
The ACTIS™ Hip Stem’s patented1 design offers proven implant stability2, with over 400,000 in clinical use3. The ACTIS Hip Stem is powered by enabling technologies KINCISE™ Surgical Automated ...
Depuy Synthes
... to total hip arthroplasty. REDUCED PROXIMAL LATERAL DESIGN The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, ...
Trilliant Surgical
Femoral stem length: 70, 105 mm
Femoral stem offset: 15, 22 mm
... Streamlined instrument set for a straightforward workflow LINK is one of the pioneers of anatomical and neck preserving prosthesis designs and has decades of experience in the development of these stem types. The ...
Waldemar Link
Femoral stem length: 16, 10 mm
Acetabular cup diameter: 46 mm - 66 mm
CCD angle: 127, 132 °
The Cordera™ Hip System, is an uncemented, primary total hip replacement featuring an industry proven stem design. The implant system can be used with or without a ...
Merete brought the BioBall® system onto the market as a “modular joint prosthesis system” at the end of the 1990s. It has become the “standard” in hip athroplasty. The titanium BioBall® adapter allows ...
Femoral stem length: 117.5, 79.5 mm
Femoral stem offset: 41.4, 32.2 mm
... patients. Conserving bone MiniHip is designed to provide the bone preserving benefits of hip resurfacing with the stability of traditional total hip replacement. With MiniHip, typically a mid-neck ...
Corin
Femoral stem length: 114, 81 mm
Femoral stem offset: 50, 29 mm
CCD angle: 128, 133, 124 °
A contemporary total hip arthroplasty system engineered for reproducibility, performance and efficiency. System Features Titanium Coating Delivers a press-fit into the acetabulum. Polished and Anodized distal ...
Femoral stem length: 130, 144, 150 mm
CCD angle: 135 °
The stem Austin Moore offers one of the most simple and classic hip hemiarthroplasty solutions market in which the articular cartilage of the acetabulum is respected. The geometry of the section of the rods is of rectangular ...
Surgival
... disease, including osteoarthritis and avascular necrosis; - Rheumatoid arthritis; - Correction of functional deformity; - Hip bone tumour; - Nonunions, femoral neck fractures, trochanteric fractures of the proximal ...
A range of total hip implants including 6 versions of femoral stems (standard or laterlized, with or without colar, with or without cement), dual mobility cups and ceramic cups.
Dedienne santé
Femoral stem length: 200 mm
... body provides rotational stability under dynamic loading Load transferred and transmitted by the interface between the prosthesis and cancellous bone Absolute mechanical stability Cone shaped geometric transition ...
JRI Orthopaedics
Femoral head diameter: 22.2 mm - 32 mm
CCD angle: 128 °
The EMERGENCE cemented femoral stem has been designed following the Charnley-Kerboull experience. EVOLUTIS wished to simplify its use on a everyday basis and changed the original neck management system (combination of length and intra-medullar ...
EVOLUTIS
Femoral stem length: 40, 50, 60, 70 mm
CCD angle: 125, 135 °
The SMR 100's stem is a modular system designed for hip replacement in particular cases of dysplasia, osteotomies and fractures. The stem features 3 components: proximal, distal and locking screw. INDICATIONS Dysplasia; Osteotomy ...
Often used for trauma cases. Wide size range of outside diameter, inside diameter is 28 mm. Ideal in those cases when femoral head cannot be saved.
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining