- Secondary care >
- Orthopedic surgery >
- Revision hip prosthesis
Revision hip prostheses
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/80816-20365006.jpg)
... Reduced A-P portions of the collar designed to allow osteotome access in the event of revision and improve range of motion. Ease of insertion The implant is designed with a reduced proximal lateral ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/128975-19975392.jpg)
Revision Hip Replacement (Acetabular Ring&Modular Stem)
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/70896-20085383.jpg)
Femoral stem length: 190, 240, 300 mm
The REDAPT Revision Femoral System is designed to offer an efficient surgical technique that allows the implant to be placed at the required level. It is designed to provide reproducible* stem positioning ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/78010-12130722.jpg)
The Revelation® Lateral Flare® Total Hip System was designed based on a more complete understanding of hip joint biomechanics and bone morphology. By loading the lateral femur, the Revelation Hip ...
Enovis Surgical
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/79814-19013065.jpg)
Femoral stem length: 290, 140, 190, 240 mm
... Modular Revision Hip System combines advances in strength, fixation, and instrumentation to optimize both the surgical and clinical experience during moderate to complex hip revision ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/83887-18592823.jpg)
... to total hip arthroplasty. REDUCED PROXIMAL LATERAL DESIGN The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, ...
Trilliant Surgical
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/86297-18634615.jpg)
Merete brought the BioBall® system onto the market as a “modular joint prosthesis system” at the end of the 1990s. It has become the “standard” in hip athroplasty. The titanium BioBall® adapter allows ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/4581069-20177350.jpg)
Femoral head diameter: 22 mm - 36 mm
... Locking design easy to install and avoid head dislocation. Push with the key when revision surgery is needed or the ball head should be changed Two-center design ensures the hip joint the greatest motion ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/69675-16539706.jpg)
Femoral stem length: 130, 420 mm
Femoral head diameter: 11 mm - 30 mm
The MRP-TITAN hip revision system is a cementless revision implant for use in the femur. The MRP-TITAN in combination with the modular revision support ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/75680-18571554.jpg)
1.Severe varus/valgus deformity with severe flexion contractrue,and need to release bilateral accessory ligaments completely. 2.Severe and uncorrected imbalance of flection gap,and lead to cam separation in non-limited design. 3.The ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/68444-18159453.jpg)
Femoral head diameter: 22 mm - 40 mm
CCD angle: 135, 128 °
The design rationale of the HACTIV implant is based on the self-blocking concept. The cementless versions are made of titanium alloy and coated hydroxyapatite. The cemented versions are made of high nitrogen content stainless ...
![revision hip prosthesis](https://img.medicalexpo.com/images_me/photo-m2/123656-18130356.jpg)
Femoral stem length: 75, 200 mm
CCD angle: 135 °
... abductor leverage by optimizing hip stability. The modularity permits intraoperative assembly, making it possible to customize the implant for each specific need. SMR & SMR Resection The distal component ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining