- Hygiene >
- Sterilization >
- Sterilizer with vacuum cycle
Sterilizers with vacuum cycle
For this sterilization method, two processes are distinguished: the vacuum sterilization process and the overpressure sterilization process. Thus, before purchasing a new system, you must first choose the right process ...
1. Double door "seal interlock", to achieve the front and rear doors "seal interlock", this structure not only can make the front and rear doors safe interlock, but also can make the supply room sterile area and contaminated area of the air
Beijing Baixiang New Technology
Capacity: 19 l - 23 l
Carrying capacity: 45 kg - 48 kg
Temperature range: 115 °C - 134 °C
... sterilization cycles 06. Bowie&Dick, Vacuum test and Test Helix 07. Automatic regulation of the temperature 08. Light at the beginning of the cycle; Sound indication ...
Tianjin Chaotuo Medical Equipment
Capacity: 50 l
Width: 600 mm
Height: 980 mm
... a powerful vacuum pump for thorough inside-out sterilization of tubal instruments. Features: Pre & post vacuum B.D. & Pump test diagnostics Prion preset program Auto water fill ...
LAOKEN bench top steam sterilizers can be applied to dental clinics, dental department of hospitals, ophthalmology department, operating rooms and so on. It can sterilize A, B class cavity instruments, dressing material, ...
Capacity: 21.5 l
Temperature range: 121 °C - 135 °C
Width: 513 mm
... chamber. 1. Unique B Class small steam sterilizer with economical and practical merits This sterilizer is an economic B-class sterilizer that is designed to remove air in the chamber ...
Hanshin Medical
Capacity: 90 l
Temperature range: 37 °C - 54 °C
Sterilization cycle time: 8 h
... Pressure Ventilation after sterilization is done in the same cabinet. Ethylene Oxide residues are 100% removed with the vacuum pump system. All heat-resistant or non-heat-resistant materials. plastics Tires/Rubber Metals Mechanical ...
Med Tip
Capacity: 16 l
Temperature range: 105 °C - 134 °C
Width: 444 mm
... a perfect hygiene Absolute safety: in case of malfunction the autoclave stops working, unloading the pressure and displaying the anomaly. La Tau Clave 3000 Vacuum is a class S autoclave ...
... humidity in the chamber. These vacuum machines operate at atmospheric pressure levels (not suitable for pressurised operation) and are not required to comply with PED. To optimise the process, we equip our machines ...
Ser.com. srl
Temperature range: 45 °C - 60 °C
Sterilization cycle time: 30 min - 45 min
... Dosage volume of H2O2(ml): Fast: 3mL/cycle; Standard:6mL/cycle; Flexi Endo: 6ml/cycle Cycle QNT/cassette: Fast:12 cycles; Standard:6 cycles; ...
Sichuan Carevision Medical Technology Co.,ltd
Capacity: 30 l - 150 l
Temperature range: 50 °C - 134 °C
◆ Hand wheel type door opening structure ◆ Mechanical safety interlocking device ◆ Computer controlled automatic cycle sterilization program ◆ Digital window LCD display working status ◆ Temperature can be set arbitrarily ...
Capacity: 16, 20 l
Temperature range: 121, 134 °C
... C11 Sterilization cyclesPossibility of two “special cycles” fully programmableVacuum test and Bowie & Dick testPrion cycle, Night cycle, Fast cycleAmpoule Cycle. Spores ...
reverberi
Capacity: 35, 50, 75, 100 l
Temperature range: 134 °C
Sterilization cycle time: 4 min - 120 min
Hand wheel translation and quick opening structure Three times pre-vacuum High quality stainless steel material Microcomputer automatic control, arbitrary setting sterilization parameters Safety interlocking device LED ...
Capacity: 24 l
Temperature range: 105 °C - 134 °C
Sterilization cycle time: 0 min - 99 min
... European Class B standard, with three-pulse pre-vacuum and post-vacuum drying functions, and the residual humidity of the equipment is less than 0.2%. 2, LCD display working status, touch key. 3. ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining