- Laboratory >
- Laboratory medicine >
- Test kit
Test kits
... can be used on GENEQUALITY X120 platform Easy interpretation of results with AB Genius Report software Kit content Ready-to-use reagents for Real time PCR Internal control (amplification ...
AB Analitica
Specificity: 90 %
... has been performed using ELISA assays or on closed mainframe immunoassay analysers. Now for the first time Anti-CCP testing can be performed on open chemistry systems using the new Axis-Shield Clinical Chemistry Anti-CCP ...
Axis-Shield PLC
Cardiovascular disease (CVD) is the number one cause of death wordwide1. The cause of CVD is atherosclerosis. Cardiovascular risk does not correlate with clinical symptoms until considerable atherosclerotic disease progression. Consequently, ...
Numares Health
Result display time: 15 min
This kit is used to the qualitative detection of SARS-CoV-2 antigen presents in humanoropharyngeal swab and nasopharyngeal swab. Value-added Function: Ø Colloidal gold labelling technology, no device required; Ø ...
... EdgeSeq ALKPlus Assay EU was tested against a cohort of NSCLC samples previously tested by the Vysis ALK Break Apart FISH probe kit. Overall, 93% agreement was achieved between the two methods. Assay Repeatability Sixteen ...
Sars-Cov-2 Nucleic Acid Detection Kit(probe-based qrt-PCR) The remarkable advantages for our Nucleic Acid Detection kits: 1) Specificity: Sars-Cov-2 can be accurately identified by dual - target ...
... control - Anti-CD3 mAb (CD3-2) Product details Application - ELISpot Analyte - IFN-γ Reactivity - Human Specificity This kit is based on a matched pair of mAbs specific for human IFN-γ. Performance PBMC (62,500 ...
Mabtech
Result display time: 105 min
• Use of recombinant human thyroid peroxidase (TPO) • Ready-to-use (exception: wash buffer) and barcoded reagents • Quality assured handling in routine laboratories • Incubation at room temperature • Quantitative ...
MEDIPAN GmbH
Result display time: 3 h - 4 h
Sample volume: 0.05 ml
... every new lot of material Enough reagents for one 96-well plate Quick turn-around time: Kits are typically shipped within 5-10 days of ordering.* Please allow additional time for international ...
R&D Systems
Specificity: 88, 95 %
Sensitivity: 100, 96 %
... M.pneumoniae IgG, IgA and IgM EIA kits provide accurate results by using highly specific antigen: P1 protein The kits come with ready-to-use, well sufficient reagents and breakable, ...
... detection kit, for amplification of signal in immunohistochemistry (IHC), immunofluorescence (IF) or in situ hybridization protocols. This kit amplifies by depositing extra DIG in the localized area of ...
Akoya Biosciences
Result display time: 45 min
Specificity: 98, 92 %
Sensitivity: 97, 91 %
Over 30 million people are at risk of invasive aspergillosis each year due to use of corticosteroids, chemotherapy or other immunosuppressive agents, and over 300,000 patients develop it annually. 1 Timely diagnosis and initiation ...
Multiple Real-Time PCR Kit for Detection of 2019-nCoV is a Real-Time RT-PCR test intended for the qualitative detection of nucleic acid from the 2019-nCoV in oropharyngeal swabs, nasopharyngeal swabs ...
BEIJING APPLIED BIOLOGICAL TECHNOLOGIES
Product Name: SARS-CoV-2 Detection Kit (Direct Fluorescence PCR) Sample Type: Oropharyngeal swab or Nasopharyngeal swab Target Gene: ORF1ab Gene, N Gene Analytical Sensitivity(LoD): 200 copies/mL Specification: ...
Zhejiang Orient Gene
... 100% Precision: CV <5% Packing Specifications 25 tests/kit (single tube for single test) - 25 tests/kit (non-single tube for single test) ...
Yaneng Bioscience (Shenzhen) Co., Ltd.
Sample volume: 2 ml
Enzymatic method for the determination of Acetaldehyde. Based on the spectrophotometric measurement of NADH produced through the reaction, after addition of aldehyde dehydrogenase (AlDH). This rapid and simple specific enzymatic method ...
NZYTech
Result display time: 10 min
Sample volume: 0.01 ml
... Virus Ag Test Combo Kit FIV/FeLV Release date - September 23, 2016 Specifications - Target animal - Cats Meas. principle - Immunochromatographic method Sample amount - Approx. 10μL per ...
Arkray
Result display time: 15 min
Sensitivity: 96, 67 %
... quick test for Legionella longbeachae. So you have clear insight for initiating the right treatment for the best possible outcome. AS EASY AS 123 Get results fast in 3 simple steps 1.INTRODUCE SAMPLE Add ...
SSI Diagnostica
... HPV One qPCR Kit is designed for quick initial screening of individuals for the presence of all 14 High Risk human papilloma virus (HPV) subtypes allowing physicians to identify those at risk for cervical cancer. This ...
GenomeMe Labs Inc
The kit is CE certified and intended for in vitro diagnostic use only. Principle The multiplex assay uses fluorescent probes and primers to detect three specific regions within the SARS-CoV-2 nucleocapsid (N) gene ...
Aurora Instruments
Sample volume: 0.2 ml
Invitek Molecular strives to produce the highest quality nucleic acid extraction products for infectious diseases, from research to diagnostics. Universal use Simultaneous isolation of viral DNA & RNA, bacterial DNA and genomic DNA One ...
Result display time: 24 h
Sample volume: 2 ml
... deterioration and affecting the test results. 2. If there is discoloration or moisture absorption on the appearance of the paper, it should be stopped from use to avoid false positive results. 3.The pH value of ...
Changchun Wancheng Bio-Electron Co., Ltd.
Specificity: 99 %
Sensitivity: 95 %
... Introduction of Brucella Antibody Competitive ELISA Kit The brucella antibody ELISA kit is based on competitive ELISA to measure the amount of brucella ...
Ring Biotechnology Co Ltd.
Result display time: 60 min
... extra components. Both cups have patents pending and are exclusively available from Advin Biotech. A Revolutionary Drug Test Cup The iSplit cup is a new innovation from Advin Biotech. Using no additional steps ...
Advin Biotech, Inc.
... serum/plasma/cerebrospinal fluid, we provide our traditional immunoenzymatic kits ELISA-VIDITEST and MONO-VIDITEST and the IF-VIDITEST immunofluorescence kit. VIDITEST kits comes from ...
VIDIA s.r.o
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining