Result display time: 25 min
... followed by Vitamin D2 (ergocalciferol), known together as calciferol. Calciferol primarily undergoes hydroxylation in the liver to 25-OH Vitamin D (calcidiol), the major circulating form of vitamin ...
Result display time: 14 min
... results, CLIA, high sensitivity ● Cost-effective, no unnecessary waste, single-use cartridge ● Comprehensive solutions, multi-test parameters ● Easy to use, only 3-step operation with whole blood testing ● Fast, 13.5 ...
... total vitamin B12 tests. Product specifications Measures the concentration of active vitamin B12 (holotranscobalamin) available to the cells Proven ELISA technology, ...
Sample volume: 0.05 ml
... of vitamin D status is the serum concentration of 25OH vitamin D. For a correct diagnosis of vitamin D deficiency, the assay must recognize two vitamins important in ...
VB12 Detection kit FA Detection kit FERRITIN Detection kit hGH Detection kit IGF-1 Detection ...
... human serum and plasma. Storage Conditions and Expiration Date Stable for 18 months when stored at 2-30 ℃ away from light. Reagents are used immediately upon opening. See label for details of production and expiry dates. Applicable ...
Nanjing Poclight Biotechnology Co., Ltd.
... plasma. PRODUCT DETAILS Storage Conditions and Expiration Date Stable for 18 months when stored at 2-30 ℃ away from light. Reagents are used immediately upon opening. See label for details of production and expiry ...
Nanjing Poclight Biotechnology Co., Ltd.
Poclight Vitamin D Reagent Test Kit, this assay is intended for the quantitative determination of total 25-hydroxyvitamin D in human serum and plasma. This assay is to ...
Nanjing Poclight Biotechnology Co., Ltd.
... determination of vitamin B12 (VB12) in human serum or plasma, it is mainly used as an auxiliary diagnostic tool for macrocytic anemia in clinical practice. For in vitro diagnostic use only. For professional use only. TEST ...
... 0.956 Test results should be interpreted at 15 minutes Used as an aid to assessment of Vitamin D levels Product Description Diagnostic Kit for 25-Hydroxyvitamin D (25-OH-VD) ...
Sample volume: 0.1, 0.05 ml
... biochemical markers like phosphorus, calcium and potassium in blood, and regulatory hormones of bone metabolism like 25-hydroxy vitamin D (25OH-VD) and its metabolites, parathyroid hormone (PTH), calcitonin (CT) and also ...
Autobio Diagnostics
Result display time: 15 min
25-OH-VD Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of 25-OH-VD inhuman serum and plasma samples. This test may help understand the metabolic ...
YHLO also supports a series of routine tests to meet different clinical needs, including Thyroid, Tumor Markers, Fertility, Anemia, Cardiac Markers, Liver Fibrosis, Metabolism, and Bone Metabolism. Immunoassay ELISA ...
This ELISA is intended for the quantitative determination of 1,25-dihydroxyvitamin D in serum and plasma. For research use only. Not for use in diagnostic procedures. Specifications Regulatory Status Research Use ...
Result display time: 90 min
Vitamin D is a fat-soluble vitamin that is involved in calcium-phosphorus metabolism. It exists in two forms: cholecalciferol (Vitamin D3), and ergocalciferol (Vitamin ...
... proteins carrying no vitamin. The major fraction in the circulation, HoloHC, represents 70-90% of vitamin B12 in the blood but is biologically inert. HoloTC represents only 10-30% of vitamin ...
Result display time: 15 min
Sample volume: 0.4 ml
... 25-OH Vitamin D3 HPLC Assay kit is intended for the quantitative determination of 25-OH Vitamin D3 in plasma and serum. The 25-OH Vitamin D3 HPLC Assay ...
... CATEGORY - TESTS/KIT Histamine - ALLERGY - 96 Tests Human IgG Food Allergy - ALLERGY - 96 Tests Human IgG4 Food Allergy - ALLERGY - 96 Tests Total ...
his test kit is suitable for quantitative detection of 25-hydroxy Vitamin D (25-(OH)VD ) in human serum/plasma sample in vitro, which is mainly used to assess vitamin ...
Result display time: 20 min
... antioxidative efficiency. BQC ABTS Assay Kit is recommended for the total antioxidant activity of solutions of pure substances, aqueous mixtures, and beverages. Additional information Sizes: ...
Bioquochem
Result display time: 25 min
Sample volume: 0.1 ml
... rickets in children and osteomalacia in adults. Vitamin D is also involved in the regulation of autoimmunity, metabolic function, and cancer prevention. Vitamin D tests are used to detect ...
Result display time: 10 min
Intended Use This kit is used to quantitatively detect the concentration of vitamin B12 (VB12) in human serum or plasma samples in vitro. Epidemiology Vitamin B12, also called cobalamin, ...
... range of AMP ELISA Tests enables detection of hormones (fertility, steroids, thyroid) tumor markers infectious diseases and a few more other parameters. The use of high-quality raw materials ...
... hydroxyvitamin D (25-oh-vit-d) detection kit(Magnetic Solid Phase Chemiluminescent Immunoassay) Packaging: 24 T/KIT Purpose of the test Vitamin D testing is used ...
Result display time: 28 min
... , which is an ichroma test reagent. 6 different slot / Independent temperature control system Independent time control In Your Medical Field Vitamin D plays an essential role in making strong ...
Storage Condition: Reagent kits should be stored at 2-8℃ and be used within the expiration date. Prothrombin reagents should be stored airtight at 2-8oC after dissolution for up to 7 days. Do not freeze. Package ...
... Quantitative Test 25(OH)-D is a prehormone that is produced in the liver by hydroxylation of vitamin D3 (cholecalciferol) by the enzyme cholecalciferol 25-hydroxylase. Physicians worldwide measure this ...
This kit is used to quantitatively detect the content of high-density lipoprotein cholesterol in human serum in vitro. Background of Clinical Indications It is used for the auxiliary diagnosis of cerebrovascular ...
Zhejiang Kangte Biotechnology Co., Ltd.
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining