Our Ultimate PLus decontamination system has been designed to offer our customers a modular, scalable decontamination solution capable of treating liquid effluents from 3,000 to 12,000 liters per hour.
The equipment can grow with you according to your production levels: it consists of a 3,000-liter/hour ULTIMATE base to which up to 3 3,000-liter/hour extensions can be added according to your flow capacity
requirements for maximum flexibility.
Operation
Decontamination capacity of main skid: 3,000 liters/hour
Decontamination capacity of each extension: 3,000 liters/hour
Up to 3 extensions of 3,000 liters/hour can be connected, for a total of 12,000 liters/hour
Recommended daily operation: up to 16 hours per day
The Ultimate 3000 is based on a modular structure that allows processing throughput to be increased by adding parallel passes.
The basic module comprising the essential equipment components operates in the same way as an Ultimate 1000 lph.
The main difference between the Ultimate 3000 and the Ultimate 1000 is that the Ultimate 3000 has pumps enabling a flow range from 3,000 to 12,000 l/h at constant pressure.
The flow rate per exchanger is fixed at 3,000 l/h, and can be increased by adding parallel-pass exchangers. Each exchanger is equipped with its own heating and flow rate control, enabling management of different levels of fouling between the different exchangers without creating a preferential circuit
Fully automated, the supervision system controls every stage of the process (from collection of contaminated liquid to discharge of decontaminated liquid), ensuring safe operation and total traceability.