Medical gas pressure regulator AM-RS
medicaltwo-stageadjustable-flow

Medical gas pressure regulator - AM-RS - AMCAREMED TECHNOLOGY - medical / two-stage / adjustable-flow
Medical gas pressure regulator - AM-RS - AMCAREMED TECHNOLOGY - medical / two-stage / adjustable-flow
Medical gas pressure regulator - AM-RS - AMCAREMED TECHNOLOGY - medical / two-stage / adjustable-flow - image - 2
Medical gas pressure regulator - AM-RS - AMCAREMED TECHNOLOGY - medical / two-stage / adjustable-flow - image - 3
Medical gas pressure regulator - AM-RS - AMCAREMED TECHNOLOGY - medical / two-stage / adjustable-flow - image - 4
Add to favorites
Compare this product
 

Characteristics

Fluid type
medical gas
Applications
medical
Number of stages
two-stage
Features
adjustable-flow, double
Flow

150 l/min
(39.63 us gal/min)

Inlet pressure

Max.: 10 bar
(145 psi)

Min.: 8 bar
(116 psi)

Output pressure

Max.: 5 bar
(72.5 psi)

Min.: 3 bar
(43.5 psi)

Description

Dual Line Regulating Station is mainly used on the floor of the ward or the gas inlet of the operating room to adjust the pressure of the pipeline to a certain pressure range. It is also used to open/cut the pipeline passage in this area for easy maintenance of pipelines and equipment. Product Detail Amcaremed medical gas pressure regulating station is painted with stainless steel and can be mounted on the wall. The front pressure observation window uses transparent plexiglass. The front of the box is equipped with a safety lock. Generally, the front door is locked to prevent others from opening it easily. If an emergency occurs, the box door can be quickly opened to quickly cut off the medical gas passage. Dual line regulating station can control the pressure of the medical gas pipeline at 3~5bar. It can also buffer the pipeline pressure, reduce the impact on the patient and the application risk. The vacuum suction pump system and the AGSS system don’t need to be decompressed. Medical gases such as oxygen, compressed air, and nitrogen dioxide generally are generally installed dual line regulating station in the pipeline for decompression. Specifications Transparent window Dual line, one for normal operation and one for backup The gas leakage valve is set to adjust the output pressure Built-in safety valve Equipped with emergency security lock, to open the door quickly in case of emergency

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall H8 - Stand F59

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.