Cementless femoral stem ACOR® monobloc
rightleft

Cementless femoral stem - ACOR® monobloc - Amplitude Surgical - right / left
Cementless femoral stem - ACOR® monobloc - Amplitude Surgical - right / left
Cementless femoral stem - ACOR® monobloc - Amplitude Surgical - right / left - image - 2
Cementless femoral stem - ACOR® monobloc - Amplitude Surgical - right / left - image - 3
Cementless femoral stem - ACOR® monobloc - Amplitude Surgical - right / left - image - 4
Cementless femoral stem - ACOR® monobloc - Amplitude Surgical - right / left - image - 5
Add to favorites
Compare this product
 

Characteristics

Fixation type
cementless
Side
right, left
Femoral stem length

98 mm, 134 mm
(3.86 in, 5.28 in)

CCD angle

129 °, 137 °

Description

The monoblock version is available in Standard and Lateralised models. Grooves increase the bone-implant contact area; they are closed proximally and open distally. Proportionately scaled sizes. Impaction limit corresponds to HAP boundary. Material: Titanium. Coating: Uniform 80 µm thick HAP. Anatomic 8° metaphyseal curvature matches the proximal femur's natural curvature. Primary stability ensured by ovoid metaphyseal cross-section that optimises metaphyseal filling. Its length and diameter make it easy to implant through the anterior approach. Thin, cylindrical distal end contributes to metaphyseal anchoring and ensures diaphyseal guiding. The joint centre of the Standard stem corresponds to a modular ACOR® stem with A/R neck and regular anteversion/retroversion values. The joint centre of the Lateralised stem corresponds to a modular ACOR® stem with L+/M+ neck in the lateral position. Femoral stem product available in several versions: - Modular. - Monoblock. ACOR® instrumentation can be used during conventional surgery or with Computer Assisted Surgery (AMPLVISION®): - Computer Assisted Surgery of the cup and femoral stem helps to maintain leg length and offset. Several broach handles suitable for the various hip approaches are available for use with or without AMPLIVISION®: - Posterior approach. - Anterior approach with patient on their side. - Anterior approach with patient supine. - Anterior Hueter approach with patient supine.

Catalogs

No catalogs are available for this product.

See all of Amplitude Surgical‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.