Descending thoracic aorta stent graft E-vita® Open Neo
aortic archnitinolePTFE

descending thoracic aorta stent graft
descending thoracic aorta stent graft
descending thoracic aorta stent graft
descending thoracic aorta stent graft
descending thoracic aorta stent graft
descending thoracic aorta stent graft
descending thoracic aorta stent graft
Add to favorites
Compare this product
 

Characteristics

Type
aortic arch, descending thoracic aorta
Material
nitinol, ePTFE
Diameter

22 mm, 24 mm, 28 mm, 30 mm, 40 mm
(0.866 in, 0.945 in, 1.102 in, 1.181 in, 1.575 in)

Length

120 mm, 130 mm, 180 mm
(4.724 in, 5.118 in, 7.087 in)

Description

Based on over ten years of clinical experience, E-vita Open Neo is the next-generation hybrid graft system for aortic arch and descending thoracic aorta repair with the Frozen Elephant Trunk technique. ADAPTING TO PATIENT’S DISEASE Each disease requires unique technique and oversizing strategies. E-vita Open Neo has been created with three stent graft configurations and dedicated designs of the vascular and stent graft sections. The three diameters of the vascular section allow for reproducible anastomosis. The full range of options of the stent graft section provides adequate oversizing for both aneurysms and dissections.1   CONTROL IN YOUR HANDS The new compact delivery system allows easy positioning of the device, and deployment can be performed in a controlled fashion with progressive expansion of the stent graft section.1 Clinical Evidence E-vita Open Neo: A Patient-Tailored Approach to the Frozen Elephant Trunk Technique1 Dr. Wong’s experience: The E-vita Open Neo covers a lot of the unmet needs of FET. Z-shape stent design could reduce the risk of dSINE as it exerts less focal stress to the aortic wall. The new delivery system is compact and easy to use compared with the former systems. E-vita Open Neo: A Patient-Tailored Approach to the Frozen Elephant Trunk Technique1 Prof. Song’s experience: Trifurcated configuration is easier and safer. The trifurcated type has an advantage in zone 0 or 1 anastomoses over the branched type in regard to angulation and space of the head vessel branch. E-vita Open Neo Hybrid Stent Graft: A New Frontier for Total Arch Replacement 2 A versatile system for each patient’s needs.

VIDEO

Catalogs

No catalogs are available for this product.

See all of Artivion‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.