Cardiovascular disease test kit 00027C
fluorescence immunoassaycassette

Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette
Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette
Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette - image - 2
Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette - image - 3
Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette - image - 4
Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette - image - 5
Cardiovascular disease test kit - 00027C - Beijing O&D Biotech Co., Ltd. - fluorescence immunoassay / cassette - image - 6
Add to favorites
Compare this product
 

Characteristics

Applications
for cardiovascular diseases
Analysis mode
fluorescence immunoassay
Format
cassette
Result display time

15 min

Sample volume

0.075 ml
(0.00254 US fl oz)

Description

Myeloperoxidase (MPO) enzyme is found in neutrophil primary granules and monocyte lysosomes. MPO catalyzes the conversion of hydrogen peroxide to hypochlorite and hypochlorous acid. MPO is encoded by a single gene that undergoes posttranslational modification to produce the active enzyme found in leukocytes. Autoantibodies to MPO (MPO antineutrophil cytoplasmic antibodies: ANCA) occur in several diseases and may be involved in the pathogenesis of vascular inflammation in patients with microscopic polyangiitis (MPA). Patients with MPA often develop MPO ANCA and may present with azotemia secondary to glomerulonephritis (pauci-immune necrotizing glomerulonephritis). MPO ANCA are not specific for MPA, and also may be detected in patients with systemic lupus erythematosus with or without lupus nephritis, Goodpasture syndrome and Churg-Strauss syndrome. Lupus nephritis and Goodpasture syndrome, as well as Wegener granulomatosis may present with azotemia and progressive renal failure. It is not possible to distinguish among these diseases on the basis of clinical signs and symptoms; autoantibody testing may be helpful. Sample vol. 75μL Working range 10-1000 ng/mL Performance CV≦15% Storage 2-30℃ Shelf Life 12 months

VIDEO

Other Beijing O&D Biotech Co., Ltd. products

Fluorescent Immunoassay (FIA) Test Kit

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.