Semi-automatic ESR analyzer SD-100
for clinical diagnosticsample preparation

Semi-automatic ESR analyzer - SD-100 - Beijing Succeeder Technology Inc. - for clinical diagnostic / sample preparation
Semi-automatic ESR analyzer - SD-100 - Beijing Succeeder Technology Inc. - for clinical diagnostic / sample preparation
Semi-automatic ESR analyzer - SD-100 - Beijing Succeeder Technology Inc. - for clinical diagnostic / sample preparation - image - 2
Add to favorites
Compare this product
 

Characteristics

Operation
semi-automatic
Applications
for clinical diagnostic, sample preparation

Description

1. Support both ESR and HCT simultaneously. 2. 20 test positions, 30 minutes of ESR test. 3. Internal printer. 4. LIS support. 5. Excellent quality with cost effective. Product Detail Analyzer Introduction SD-100 Automated ESR Analyzer adapts to all level hospitals and medical research office, it’s used to test erythrocyte sedimentation rate (ESR) and HCT. The detect components are a set of photoelectric sensors, which can make detection periodically for 20 channels. When inserting samples in channel, detectors make response immediately and begin to test. Detectors can scan samples of all channels by periodical movement of detectors, which makes sure when the liquid level changes, detectors can collect displacement signals exactly at any moment and save the signals in built-in computer system. Features 1. Designed for Large-level Lab with PT 360T/D. 2. Viscosity based (Mechanical clotting) assay, immunoturbidimetric assay, chromogenic assay. 3. Internal barcode of sample and reagent, LIS support. 4. Original reagents, cuvettes and solution for better results. Precautions For Use: 1. The anticoagulant should be 106mmol/L sodium citrate, and the ratio of anticoagulant to blood drawn volume is 1:4. 2. Do not insert the erythrocyte sedimentation tube into the test channel when powering on the self-test, otherwise it will cause abnormal self-test of the channel. 3. After the system self-inspection is over, the capital letter "B" is marked in front of the channel number, which indicates that the channel is abnormal and cannot be tested. It is strictly forbidden to insert the ESR tube into the test channel with abnormal self-inspection.

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.