Creatinine reagent kit CRE-10 series
solutionfor biochemistryliquid

Creatinine reagent kit - CRE-10 series - BILIMSEL TIBBI ÜRÜNLER - solution / for biochemistry / liquid
Creatinine reagent kit - CRE-10 series - BILIMSEL TIBBI ÜRÜNLER - solution / for biochemistry / liquid
Add to favorites
Compare this product
 

Characteristics

Type
solution
Applications
for biochemistry
Format
liquid
Tested parameter
hemoglobin, hydrogen peroxide, creatinine, bilirubin
Method
enzymatic
Storage temperature

Min.: 2 °C
(36 °F)

Max.: 8 °C
(46 °F)

Description

For the in vitro quantitative determination of Creatinine in serum and urine METHODOLOGY In the first reaction,creatinase and sarcosine oxidase were used in the enzymatic hydrolysis of endogenous creatine to produce hydrogen peroxide ,that is eliminated by catalase .In the second reaction ,the catalase is inhibited by sodium azide and creatinase and 4- aminoantpyrine (4-AAP) were added,and only the creatine generated from creatinine by creatininase was hydrolyzed sequentially by creatinase and sarcosine oxidase to produce hydrogen peroxide.This newly-formed hydrogen peroxide was measured in a coupled reaction catalyzed by peroxidase,with N-ethyl-nsulphopropyl-m-toluidine (TOPS)/4-AAP as a chromogen. REAGENT PREPARATION Reagents are supplied in a two vial, ready to use, liquid form. PRECAUTIONS Reagent 1 contains MOPS ; R36/37/38 Irritation to eyes,respiratory system and skin. Keep locked up ,Keep out of the reach of children. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Wear suitable protective cloth gloves and eye/face protection. REAGENT DETERIORATION The reagent should not be used if: 1. The reagent is cloudy (contaminated). 2. The reagent fails to meet stated parameters of performance. INTERFERENCES 1. Studies to determine the level of interference for hemoglobin and bilirubin, were carried out, the following results were obtained: Hemoglobin: No significant interference from hemoglobin up to 5 g/dL. Bilirubin: No significant interference from bilirubin up to 40 mg/dL. 2. Some drugs and substances may interfere accuracy of the creatinine.

Catalogs

No catalogs are available for this product.

See all of BILIMSEL TIBBI ÜRÜNLER‘s catalogs

Other BILIMSEL TIBBI ÜRÜNLER products

Universal Bottled Clinical Chemistry Reagents

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.