Hot air laboratory incubator CB 56
CO2medicalvertical

Hot air laboratory incubator - CB 56 - BINDER GmbH - CO2 / medical / vertical
Hot air laboratory incubator - CB 56 - BINDER GmbH - CO2 / medical / vertical
Hot air laboratory incubator - CB 56 - BINDER GmbH - CO2 / medical / vertical - image - 2
Hot air laboratory incubator - CB 56 - BINDER GmbH - CO2 / medical / vertical - image - 3
Hot air laboratory incubator - CB 56 - BINDER GmbH - CO2 / medical / vertical - image - 4
Hot air laboratory incubator - CB 56 - BINDER GmbH - CO2 / medical / vertical - image - 5
Add to favorites
Compare this product
 

Characteristics

Type
hot air, CO2
Applications
medical
Configuration
vertical
Chamber material
stainless steel
Number of doors
1-door
Other characteristics
constant
Temperature range

Min.: 4 °C
(39.2 °F)

Max.: 60 °C
(140 °F)

Capacity

53 l
(14 gal)

Description

Safe – cell cultures receive maximum protection against contamination Reliable – constant well-being conditions for the cells Smart – simple routine cleaning and convenient operation Economical – efficient operation without consumables Product description The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories. Important characteristics Optimized humidification system with condensation protection Tried-and-tested anti-contamination concept with 180°C hot air sterilization Hot-air sterilizable CO₂ sensor with single-beam infrared technology Seamless inner chamber made of stainless steel with flanges as shelf support system Fanless interior with Venturi CO₂ gas mixing nozzle Intuitive touchscreen controller Internal data recording, can be read out in open format via USB interface Fault diagnosis system with visual and acoustic alarm Interfaces:Ethernet, USB, zero-voltage alarm contact Fail-safe CO₂ system for protecting the pH of cell cultures Performance Data Climate Designation - CB056-230V CB056UL-120V Humidity range - 90 ...95 % RH - 90 ...95 % RH Gas Data CO₂ range - 0 ...20 Vol.-% CO2 - 0 ...20 Vol.-% CO2 CO₂ measuring technology - IR - IR CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ - 5 min - 5 min Electrical data Rated Voltage - 200...230 V - 100...120 V Power frequency - 50/60 Hz - 50/60 Hz Nominal power - 0,8 kW - 0,8 kW Unit fuse - 10,0 A - 16,0 A
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.