Characteristics

Evaluation type
pressure, flow
Applications
medical
Other characteristics
ultrasonic

Description

The ultrasonic flowmeter Type 8081 is designed for measuring the flow rate of water, also with water with low levels of contamination. It consists of an electronic module and a brass fitting with integrated measurement tube. A flow control system can be set up very easily by combining the device with a controller and a control valve. The electrical connection is via a 5-pole M12 device plug. Depending on the variant, the device comes fitted with the following outputs: - a pulse output or - a pulse output with a 4-20 mA current output. Every variant comes with 5 The ultrasonic flowmeter Type 8081 is designed for measuring the flow rate of water, also with water with low levels of contamination. The device consists of a brass fitting with integrated measurement tube and a transmitter. It is available in 5 variants: QN 0.6 DN 15, QN 1.5 DN 15, QN 2.5 DN 20, QN 3.5 DN 25, QN 6.0 DN 25 with flow volumes ranging from 0.06 l/m to 20 l/min (nominal flow rate 0.6 m3/h, i.e. 10 l/min), from 0.1 to 50 l/min (nominal flow rate 1.5 m3/h, i.e. 25 l/min), from 0.16 to 82 l/min (nominal flow rate 2.5 m3/h, i.e. 41 l/min), from 0.6 to 116 l/min (nominal flow rate 3.5 m3/h, i.e. 58 l/min), or from 1 to 200 l/min (nominal flow rate 6.0 m3/h, i.e. 100 l/min Each variant is fitted either with a pulse output or a pulse output and a 4-20 mA current output. The electrical connection is via a 5-pole M12 plug. A control circuit can be created by combining the device with a controller and a control valve. Ultrasonic flowmeter operating according to the time of flight (TOF) principle Dynamic area ≥ 1:250 Minimal pressure loss No calming sections required at the inlet or outlet

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Hyvolution 2025
Hyvolution 2025

28-30 Jan 2025 paris (France) Stand 6H31

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.