2/2-way - Normally Closed (NC)
Series PDV directly operated solenoid valve is available with several nominal diameters and in three different versions according to the electrical connection.
Moreover, the fluid separation membrane protects the medium from extreme changes of temperature due to heating of the solenoid.
To choose the most suitable model for a specific application, check the chemical compatibility of the medium with the available materials of body and seals.
TECHNICAL FEATURES -
Function
2/2 NC
Operation
directly operated with fluid separation membrane
Pneumatic connections
on subbase
Orifice diameter
0.8 … 2 mm
Flow efficient kv (l/min)
0.25 ... 0.8
Operating pressure
0 ... 7 bar
Operating temperature
10 ÷ 50 °C (FKM/EPDM) / 20 ÷ 50 °C (FFKM)
Media
inert or corrosive liquids and gases compatible with the materials in contact
Response time (ISO 12238)
≤ 15 ms
Installation
in any position
MATERIALS IN CONTACT WITH THE MEDIUM -
Body
PEEK
Seals -
FKM - EPDM - FFKM
ELECTRICAL FEATURES -
Voltage
12 ... 24 V DC - other voltages on demand
Voltage tolerance
±10%
Power consumption
2 W
Duty cycle
ED 100%
Electrical connection
industrial standard (9.4 mm), DIN EN 175 301-803-C (8 mm), 300 mm flying leads
Protection class
IP65 with connector