2/2-way - Normally Closed (NC) and Normally Open (NO)
3/2-way - Normally Closed (NC) and Normally Open (NO)
Series A solenoid valves are of the directly operated type and can be used with dry or lubricated air. They are available in the 2/2 and 3/2-way versions with normally closed (NC) or normally open (NO) operation.
As shown in the following tables, they are supplied in different versions according to the type of body, threaded ports and orifice. They can thus satisfy various operating and installation requirements.
The solenoid can be easily and quickly replaced without interfering with the pressurised part of the valve.
On the same mechanical part different types of solenoids can be interchanged. The choice of solenoids determines the performance of the solenoid valve in terms of consumption and pressure.
TECHNICAL FEATURES -
Function
2/2 NC - 2/2 NO - 3/2 NC - 3/2 NO
Operation
direct acting poppet type
Pneumatic connections
M5, G1/8, R1/8 threads - Ø4 fittings - CNOMO and manifold interface- Ø6 barb fittings
Orifice diameter
1.2 ... 2.5 mm
Flow efficient kv (l/min)
0.62 … 2.0
Operating pressure
-0.9 … 15 bar
Operating temperature
0 ÷ 60 °C (-20 °C with dry air)
Media
filtered air, class 5.4.4 according to ISO 8573-1 (max oil viscosity 32 cSt), inert gas
Response time (ISO 12238)
ON <15 ms - OFF <25 ms
Installation
see tables
in any position
MATERIALS IN CONTACT WITH THE MEDIUM -
Body
nickel-plated brass - burnished brass - PA6 - PBT
Seals
HNBR, FKM
Internal parts
stainless steel
ELECTRICAL FEATURES -
Voltage
12 … 110 V DC - 24 … 380 V AC 50/60 Hz
Voltage tolerance
±10% (DC) / -15% ÷ +10% (AC)
Power consumption