2/2-way - Normally Closed (NC)
3/2-way - Normally Closed (NC), Normally Open (NO)
Series 6 solenoid valves are available as 2/2 and 3/2-way, either NC or NO.
These direct acting solenoid valves can be used either with or without lubrication.
The bodies of these valves can be used either individually or in manifolds.
The latter are provided with G1/8 threaded ports or an inbuilt diameter 4 cartridge(G3/8 for 2-way only).
TECHNICAL FEATURES -
Function - 2/2 NC - 3/2 NC - 3/2 NO
Operation - direct acting poppet type
Pneumatic connections - G1/8, G3/8 threads - ø4 fitting - CNOMO interface
Orifice diameter - 2 … 4 mm
Flow coefficient kv (l/min) - 1,2 … 5,4
Working pressure - 0 ÷ 4 … 15 bar
Working temperature - 0 ÷ 60 °C (FKM seals) / -50 ÷ 50 °C (NBR seals)
Fluid - filtered air class [5:4:4]([5:1:4] for versions -50°C) according to ISO 8573-1:2010 (max oil viscosity 32 cSt), inert gas
Response time - ON <15 ms - OFF <15 ms
Manual override - see tables
Installation - in any position
MATERIALS IN CONTACT WITH THE MEDIUM -
Body - nickel-plated brass - anodized aluminium
Seals - FKM (NBR for versions -50 °C)
Internal parts - stainless steel
ELECTRICAL FEATURES -
Voltage - 12 … 110 V DC - 24 … 230 V AC 50/60 Hz
Voltage tolerance - ±10% (DC) - +10% ÷ -15% (AC)
Power consumption - 10 W (DC) - 19 VA (inrush AC), 12 VA (holding AC)
Duty cycle - ED 100%
Insulation class - H (180°C)
Electrical connection - connector DIN EN 175 301-803-A
Protection class - IP65 with connecto