Automatic immunoassay analyzer LYOFIA8
for clinical diagnosticmicrofluidicfluorescence

Automatic immunoassay analyzer - LYOFIA8 - Chengdu Vacure Biotechnology Co., Ltd - for clinical diagnostic / microfluidic / fluorescence
Automatic immunoassay analyzer - LYOFIA8 - Chengdu Vacure Biotechnology Co., Ltd - for clinical diagnostic / microfluidic / fluorescence
Automatic immunoassay analyzer - LYOFIA8 - Chengdu Vacure Biotechnology Co., Ltd - for clinical diagnostic / microfluidic / fluorescence - image - 2
Automatic immunoassay analyzer - LYOFIA8 - Chengdu Vacure Biotechnology Co., Ltd - for clinical diagnostic / microfluidic / fluorescence - image - 3
Add to favorites
Compare this product
 

Characteristics

Operation
automatic
Applications
for clinical diagnostic
Technology
microfluidic
Analysis mode
fluorescence
Sample type
clinical, serum, plasma
Tested parameter
NT-proBNP
Configuration
benchtop
Other characteristics
with touch screen, USB
Throughput

500 p/h

Test storage capacity

10,000 unit

Description

This device is based on fluorescence immunoassay technology and intended to be used in combination with the detection kits manufactured by our company to quantitatively detect analytes in human serum, plasma or other body fluid samples in clinical practice. And it is for professional use only, not for self-testing of untrained individuals, nor for near-patient testing. Contraindications: None. Analyzer Summary This device is a quantitative determination analyzer developed basing on modern optoelectronic technology and intended to be used in combination with fluorescent immunoassay strips to detect relevant parameters of human samples. The detection results could be used for clinical auxiliary diagnosis. The analyzer applies a time-resolved method for detection. The principle is to use the characteristics of the wide Stocks shift and long duration of the lanthanide elements labeled in the test strip, that is, after removing the excitation light, the lanthanide elements can still maintain the continuous emission of the emitted light for a long time. However, other substances that can be excited to emit fluorescence cannot generate emission light in a very short time after the excitation light is removed. It is the application of the time-resolved method for detection that after turning off the excitation light for a certain period of time, and after other interfering substances cannot generate the emitted light, the light intensity is read. Through the optimized design of the optical path and the amplifier circuit, the weak fluorescence emission light signal can be detected, so as to achieve the purpose of reducing the background and interference.

VIDEO

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.