Dialyzer reprocessing machine W-F168-A
automated

Dialyzer reprocessing machine - W-F168-A - Chengdu Wesley Bioscience Technology Co.,Ltd - automated
Dialyzer reprocessing machine - W-F168-A - Chengdu Wesley Bioscience Technology Co.,Ltd - automated
Dialyzer reprocessing machine - W-F168-A - Chengdu Wesley Bioscience Technology Co.,Ltd - automated - image - 2
Dialyzer reprocessing machine - W-F168-A - Chengdu Wesley Bioscience Technology Co.,Ltd - automated - image - 3
Dialyzer reprocessing machine - W-F168-A - Chengdu Wesley Bioscience Technology Co.,Ltd - automated - image - 4
Add to favorites
Compare this product
 

Characteristics

Applications
for dialyzer
Other characteristics
automated

Description

W-F168-A /W-F168-B dialyzer reprocessing machine are the first automatic dialyzer reprocessing machine in the world, and W-F168-B with double workstation. Our perfectness comes from professional and advanced technology, that makes our products legal, safe, and stable. Product Introduction Function 1. W-F168-A /W-F168-B dialyzer reprocessing machine are the first automatic dialyzer reprocessing machine in the world, and W-F168-B with double workstation. Our perfectness comes from professional and advanced technology, that makes our products legal, safe, and stable. 2. W-F168-A / W-F168-B Dialyzer Reprocessing Machine are the main device for hospital to sterilize, clean, test and affuse reusable dialyzer used in hemodialysis treatment. 3. Procedure of Reusing Processing: [Rinse]----Using RO water to rinse dialyzer. [Clean]----Using disinfectant to clean dialyzer. [Test] -----Testing blood chamber capacity of dialyzer and whether the membrane is broken or not. [Disinfect] ---Using disinfectant to affuse dialyzer. 4. Be used in hospital only. Technical Parameter Power Supply:AC 220V±10%, 50Hz-60Hz, 2A Input power: 150W Water input pressure: 0.15~0.35 MPa (21.75 P.S.I.~50.75 P.S.I.) Water input temperature: 10℃~40℃ Minimum water Inlet flow : 1.5L/min Reprocessing time: about 12 minutes per cycle Work environment: temperature 5℃~40℃ at relative humidity of no more than 80%. Storage temperature should be between 5℃~40℃ at relative humidity of no more than 80%.