Fingertip pulse oximeter CMS50DL1
medicalbattery-poweredwireless

Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless
Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless
Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless - image - 2
Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless - image - 3
Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless - image - 4
Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless - image - 5
Fingertip pulse oximeter - CMS50DL1 - Citizen Systems Japan  - medical / battery-powered / wireless - image - 6
Add to favorites
Compare this product
 

Characteristics

Configuration
fingertip
Applications
medical
Options
battery-powered, wireless
Color
white, black
Pulse rate

Max.: 250 unit

Min.: 30 unit

Oxygen level

Max.: 100 %

Min.: 0 %

Battery life

24 h

Description

Small in size Easy to operate Low power consumption Light in weight Convenient to carry Specifications SpO2(*1) Accuracy (*2) 70 % SpO2 ~ 100 % SpO2 : ±2% SpO2; 0% SpO2 ~ 69 % SpO2 : unspecified Resolution 1 % SpO2 Plus rate Accuracy (*3) ±2 bpm or ±2%, whichever is greater Resolution 1 bpm Battery 1.5V (AAA (LR03)size) alkaline batteries x 2 Dimensions Approx. W36 ×H32 ×D61 mm *1The claims of SpO2 accuracy shall be supported by clinical study measurements taken over the full range. By artificial inducing, get the stable oxygen level to the range of 70 % to 100 % SpO2, compare the SpO2 values collected by the secondary standard pulse oximeter equipment and the tested equipment at the same time, to form paired data, which are used for the accuracy analysis. There are 12 healthy volunteers (male: 6. female: 6; age: 18~45; skin color: black: 2, light: 8, white: 2) data in the clinical report. *2Because pulse oximeter equipment measurements are statistically distributed, only about two-thirds of pulse oximeter equipment measurements can be expected to fall within ±Arms of the value measured by a CO-OXIMETER. *3Patient simulator has been used to verify the pulse rate accuracy, it is stated as the root-mean-square difference between the PR measurement value and the value set by simulator.