Portable vital signs monitor Waveline EZ
compactTEMPECG

Portable vital signs monitor - Waveline EZ - DRE Veterinary - compact / TEMP / ECG
Portable vital signs monitor - Waveline EZ - DRE Veterinary - compact / TEMP / ECG
Portable vital signs monitor - Waveline EZ - DRE Veterinary - compact / TEMP / ECG - image - 2
Add to favorites
Compare this product
 

Characteristics

Configuration
portable, compact
Measured parameter
TEMP, ECG, NIBP, IBP, RESP, etCO2, SpO2
Applications
veterinary
Technology
pulse wave analysis
Options and accessories
with touchscreen, wireless, with built-in printer
Screen size

8 in

Weight

6 lb
(2.7 kg)

Pulse rate

Max.: 240 unit

Min.: 25 unit

Oxygen level

Max.: 100 %

Min.: 1 %

Description

Featuring cutting-edge innovations and impeccable craftsmanship, the Avante Waveline EZ patient monitor is the perfect choice for healthcare professionals who demand precision, performance and affordability. Features: Simultaneous multi-lead ECG monitoring Masimo SET® Pulse Oximetry Advanced ST and arrhythmia detection Graphical and tabular trending Displays three waveforms Battery backup Audible and visual alarms Quick BP readings recall SPECIFICATIONS Safety Approval & Quality System: Designed to meet IEC60601-1-1988, EN60601-1-1, EN60601-2 Class II Equipment, double insulated Type BF applied parts ISO9001 & EN46001 Certified Power Requirements: Power Supply: AC 90-264V/47-63Hz Input Power: ≤55VA Fuses: Two fuse sockets in the rear panel indicated by “FUSE”, OI 5X20, 2A/250V Battery: 12V/4.0AH sealed lead-acid Charge time: ≥4 hours Operating time: ≥2 hours (full recharge) Battery Charging Method: Automatic charging after monitor is connected to AC power supply (with charge protection function) Discharge Protection: When powered by battery, the monitor will be automatically turned off when battery power is almost used up ECG: Patient Safety Standard: IEC60601-1-1988 CMRR ≥60dB (Common Mode Rejection Ratio) Heart Rate Range: 20 ~ 254bpm 1bpm Heart Rate Averaging: 8 second average ST Segment Range: -0.8 ~ + 0.8mV Interface: AAMI 6-pin Lead Selection: I, II, III (3 lead mode) I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis) Lead Fault Alarm: Audible, Visual Input 5-lead ECG patient cable QRS Indicator: Audible and Visual Alert Waveform Storage: 6 minutes Sweep Speed: 12.5/25/50 mm/sec Gain Selection:4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto

Catalogs

No catalogs are available for this product.

See all of DRE Veterinary‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.