Flow rate of the purified gasup to 2000
Air-pressure, kPanot more than, 6
Chimney diameter, mm500
Chimney height, mm8000
Maximum gas temperature at the outlet, °С+30…+200
Power consumption, kW27,5
Gas cleaning factor, %up to 99
Dry agent injection systemoptional
Dry gas cleaning systems are used to clean gases from solid particles of the gas-air mixture and some gaseous contaminants. In addition to purification from solid particles, dry gas cleaning system can be used to remove gaseous contaminants: sulfur dioxide (dry reagent injection is used), heavy metals, such as mercury (carbon adsorber is used).
The choice of gas cleaning system depends on the following initial indicators:
Availability of water supply, wells, delivered water;
Composition of waste;
Required level of emissions of pollutants in flue gases;
Climatic and territorial location (size of the sanitary protection zone, ambient temperature);
Equipment dimensions.
No water consumption;
A water treatment system is not required (to avoid the discharge of waste water from the Wet gas cleaning system);
Dry gas cleaning system can operate at low ambient temperatures down to -60 °С.