Biliary stent BD
polymerbioresorbableself-expanding

Biliary stent - BD - ELLA-CS - polymer / bioresorbable / self-expanding
Biliary stent - BD - ELLA-CS - polymer / bioresorbable / self-expanding
Biliary stent - BD - ELLA-CS - polymer / bioresorbable / self-expanding - image - 2
Biliary stent - BD - ELLA-CS - polymer / bioresorbable / self-expanding - image - 3
Biliary stent - BD - ELLA-CS - polymer / bioresorbable / self-expanding - image - 4
Biliary stent - BD - ELLA-CS - polymer / bioresorbable / self-expanding - image - 5
Add to favorites
Compare this product
 

Characteristics

Type
biliary
Material
polymer
Options
self-expanding, bioresorbable
Diameter

8 mm, 10 mm
(0.315 in, 0.394 in)

Length

30 mm, 40 mm, 50 mm, 60 mm, 70 mm
(1.181 in, 1.575 in, 1.969 in, 2.362 in, 2.756 in)

Description

ELLA-BD Stent Biliary THP Worldwide unique self-expandable biliary biodegradable stent that degrades in the human body usually 3 to 6 months after the implantation. Therefore, it is an ideal solution for temporary use in benign indications, where it is not necessary to extract it from the body like other non-degradable stents. INDICATION The ELLA-BD Stent Biliary THP is intended for patients aged 18 and older and is indicated for the treatment of benign biliary stenoses. FEATURES / BENEFITS Stent degrades in the human body usually in 3 to 6 months. This reduces the number of interventions and hospital visits. The stent is made of polydioxanone, an absorbable material (polymer) used in medicine as a surgical suture for more than 30 years. The stent integrity and radial force are maintained for 6 to 8 weeks after implantation. Subsequently, the radial force gradually decreases until the degradation of the material after 3 to 6 months. It eliminates the need for repeated exchange of a biliary catheter and extraction, which decreases the risk of infection or other post-procedural complications. Sufficient radial force to maintain the bile duct lumen open in benign strictures. The pH value affects the stent degradation process. The lower pH, the stent degradation is faster. Low migration is achieved by uncovered stent design. The stent is equipped with gold markers - 1 piece at both stent ends. DELIVERY SYSTEM Braided sheath. Kink-resistant. The atraumatic olive and the radiopaque ring at the end of the delivery system allow easy insertion. An option of retracting the partially released stent during implantation, up to 60% of the stent length.

VIDEO

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.