Fully automated hemostasis analyzer ECL 760
1-channelchromogenicPT

Fully automated hemostasis analyzer - ECL 760 - ERBA Diagnostics Mannheim - 1-channel / chromogenic / PT
Fully automated hemostasis analyzer - ECL 760 - ERBA Diagnostics Mannheim - 1-channel / chromogenic / PT
Fully automated hemostasis analyzer - ECL 760 - ERBA Diagnostics Mannheim - 1-channel / chromogenic / PT - image - 2
Add to favorites
Compare this product
 

Characteristics

Operation
fully automated
Number of channels
1-channel
Analysis mode
chromogenic
Test type
PT, APTT, fibrinogen
Configuration
benchtop
Other characteristics
with touchscreen, random access
Throughput

40 p/h, 60 p/h

Weight

53 kg
(116.8 lb)

Length

660 mm
(26 in)

Width

510 mm
(20.1 in)

Height

580 mm
(22.8 in)

Description

It’s an advanced, fully automated random access analyzer for Complete Hemostasis. This seven channel coagulation analyzer redefines the benefits in its class. This system is ideal for mid-high range coagulation workload, especially for routine PT, aPTT and some rare parameters. Product Features: Interactive touch screen interface/ keyboard Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors and multirules. Temperature stability at 37 degree C to perform the tests Low Reagent Consumption Windows software CE mark Product Applications: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S can be performed using Light scatter principle Protein C, Antithrombin III can be done by Chromogenic Principle Tests like D Dimer can be performed using Immuno-turbidimetry principle General Specifications: 7 channel fully automated hemostasis instrument It can perform 10 tests per profile Sample id can be 14 digits numeric, self generating id or custom id It is also possible to have continuous loading of samples It can run assays in single or duplicate (programmable per assay) The System uses the much proven light scatter principle of detection Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 575nm) Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA

Catalogs

ECL 760
ECL 760
2 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.