1. Hygiene
  2. Sterilization
  3. Medical sterilizer
  4. F. & M. Lautenschläger GmbH & Co. KG

Medical autoclave MagnoCERT
floor-standinghorizontalautomatic

medical autoclave
medical autoclave
medical autoclave
medical autoclave
medical autoclave
Add to favorites
Compare this product
 

Characteristics

Applications
medical
Configuration
floor-standing, horizontal
Function
automatic, high-capacity
Capacity

520 l, 763 l, 1,060 l, 1,505 l, 2,098 l
(137.37 gal, 201.56 gal, 280.02 gal, 397.58 gal, 554.23 gal)

Temperature range

Min.: 121 °C
(249.8 °F)

Max.: 134 °C
(273.2 °F)

Width

648 mm
(26 in)

Height

1,148 mm
(45.2 in)

Depth

700 mm, 1,028 mm, 1,428 mm, 2,028 mm, 2,828 mm
(28 in, 40 in, 56 in, 80 in, 111 in)

Description

The MagnoCERT is the steam sterilizer for the large scale sterilization facility in hospitals or industry, particularly suitable for central service providers with more than one client. At least three loading levels, highest reliability and innovative process technology guarantee minimum cycle times and maximum performance. Intelligent loading and Transport alternatives - the chamber is equipped with electrically driven horizontal sliding doors. With the installation level of the inner chamber bottom on ground level, the MagnoCERT is prepared for loading with heat and steam resistant carts. An installation above ground level requires loading a system consisting of transport and loading carts. Automatic loading and unloading blocks for minimum waiting times and optimum sterilizer output are available for various loading alternatives. Patented LAUTENSCHLÄGER door seal system - the inflatable door seal is maintenance-free for several thousand cycles. Ist design guarantees 100% leak tightness during the whole wear lifespan. Integrierted batch control and Bowie-Dick test - the patented LAUTENSCHLÄGER steam analyzer (DMA) detects non-condensable gases in the sterilizer chamber during the critical process steps. With its self-monitoring design, the DMA complies with the requirements of a failure warning system and of a Bowie-Dick test system. Individually calibrated for each sterilizer it reaches highest accuracy and reproducibility. Modern sterilization processes - LAUTENSCHLÄGER sterilization cycles with their highly efficient air removal phase minimize the risks caused by non-condensable gases ... even without thermal feed water degasification.

Exhibitions

Meet this supplier at the following exhibition(s):

GMP-Pharma Technica Expo

8-09 Apr 2025 Wiesbaden (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.