TEMP vital signs monitor
heart ratebreathingblood pressure

TEMP vital signs monitor
TEMP vital signs monitor
TEMP vital signs monitor
Add to favorites
Compare this product
 

Characteristics

Measured parameter
TEMP, heart rate, breathing, blood pressure, NIBP, SpO2
Applications
intensive care, clinical
Patient type
infant
Options and accessories
with touchscreen
Other characteristics
high-resolution
Screen size

7.5 in

Pulse rate

Max.: 280 unit

Min.: 24 unit

Oxygen level

Max.: 100 %

Min.: 0 %

Description

Neonatal Non-Invasive Blood Pressure [135mmHg] Excess-Pressure Protection. Adjustable Neonatal Breath Pause Alarm Time (15 - 20 s) Monitor Chart Trends and Reviews Up to 72 hours. Data Recoverable and Charts Can be Replayed. Oxygen Level Can be Monitored Seperately with Functions of Setting High and Low Limits of Oxygen Levels. Data Deposits and Review Functions Enable Caretakers for Further Examination. Light and Portable for External Record and Connection to Central Networks DC/AC Applicable with Internal Batteries for Up to 1.5 h Independent Power Supply. Noncontact Breathing Head Mask Is Tailored and Designed for Newborns Hear-Rate Modes Lead Input:3/5 (3 for most cases) 3-Lead Mode:Ⅰ、Ⅱ、Ⅲ 5-Lead Mode:Ⅰ、Ⅱ、Ⅲ、AVR、AVL、AVF、V Gain:2.5mm/mV,5.0 mm/mV,10 mm/mV, 20 mm/mV Wave Speed:12.5mm/s,25 mm/s,50 mm/s, Accuracy:±2% or ±1bpm Resolution:1bpm Leakage Current:<10μA Protection:Separation Tolerance 4000V,50/60Hz voltage with anti-tremor protectin Electrocardio Tabs:1mV±5% Test Range:24~280bpm(b/min) Alarm Range:100~180bpm(b/min) ST Interval Analysis:Yes Arrhythmia:Yes Arrhythmia Alarm/Review:Yes Alarm:multi-angle sound & light alarms with repetitions Blood O2 Saturation Specification Resolution:1% Accuracy:80~100%±2% 0%~79% nondescriptable Alarm Range:0~100% continuous Resolution:1bpm Accuracy:±2bpm Alarm:multi-angle sound & light Breathe Mode Mode:RA-LL impedence Resolution:1rpm Accuracy:±2rpm Asphyxiation Detection and Alarm:15~20 s (adjustable by seconds) Blood Pressure Type Measurement Method: automatic oscillation Work Mode: manual/automatic/continuous Auto-Measure Time: 1~960 min (adjustable) Measurement Unit:mmHg/KPa

Catalogs

No catalogs are available for this product.

See all of Farstar (Wuxi) Medical Equipment‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.