Portable multi-parameter monitor BM3
compactECGRESP

Portable multi-parameter monitor - BM3  - GIMA - compact / ECG / RESP
Portable multi-parameter monitor - BM3  - GIMA - compact / ECG / RESP
Add to favorites
Compare this product
 

Characteristics

Configuration
compact, portable
Measured parameter
ECG, TEMP, RESP, heart rate, NIBP, SpO2
Applications
veterinary
Technology
pulse wave analysis
Options and accessories
with built-in printer, with integrated battery
Other characteristics
continuous
Screen size

7 in

Battery life

2 h

Weight

3.1 kg
(6.8 lb)

Pulse rate

Max.: 254 unit

Min.: 30 unit

Oxygen level

Max.: 100 %

Min.: 0 %

Description

- Individual sweep speed setting for each parameter - 128 full hours trend data stored - SpO2 measurement with very low perfusion detection and pulse beep - 2 traces ECG - screen freeze on/off - connection to Central monitoring system using LAN or W-LAN - High-performance ECG detection and analysis • input impedance for dry skin or electrode patch • ST level, PVC count real-time display • 3 kinds of Arrhythmia analysis • pacemaker detection function - Enhanced data management • graphical and tabular trends • 20 cases per 10 sec alarm waveform stored, reviewed and printed - Internal software selectable in GB, DE, FR, IT, PT, PL, RO, HU, ES, CZ, BG, RU, TR, CN - User manual: GB, IT (on request: ES, FR, DE) Technical Specifications ECG • Lead type: 3-lead, 5-lead (option) • Lead selection: - 3-lead I, II, III - 5-lead I, II, III, aVR, aVL, aVF, V (option) • Heart rate range: - Adult: 30 to 300 bpm, - Neonate/Pediatric: 30 to 350 bpm • Heart rate accuracy: ± 1bpm or ± 1%, whichever is greater • Sweep speed: 6.25, 12.5, 25, 50 mm/sec • Filter: - Diagnosis: 0.05 to 150 Hz - Monitoring: 0.5 to 40 Hz - Moderate: 0.5 to 25 Hz - Maximum: 5 to 25 Hz • S-T segment detection range: -2.0 to 2.0 mV • Arrhythmia analysis: ASYSTOLE, VTACH, VFIB • Pacemaker detection mode: Indicator on waveform display (user selectable) • Protection: Against electrosurgical interference and defibrillation NIBP • Technique: Oscillometric • Measurement Modes: Manual/automatic/continuous • Pressure range: 0 to 300 mmHg ±3 mmHg • Measurement range: - Adult pressure: 20 to 260 mmHg - Pediatric pressure: 20 to 230 mmHg - Neonatal pressure: 20 to 120 mmHg
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.