1. Dental
  2. Dental practice
  3. Intraoral X-ray system
  4. Guangzhou Chuang Qi Medical Equipment
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Intraoral X-ray system CQ-X02B
wall-mounteddigital60 kV

intraoral X-ray system
intraoral X-ray system
Add to favorites
Compare this product
 

Characteristics

Type of system
intraoral X-ray system
Ergonomics
wall-mounted
Technology
digital
Tube voltage (kV)
60 kV
Focal spot size (mm)
0,8 mm

Description

Use the intermational advanced technology. high-efficiency.clear imaging low leak radial,is only 1% of national standard Light touched button,controled with microcomputer,only press one button to select the exposue parameter,fast and accurately Developing in light room,image in one minute,the doctor can diagnose conveniently for maximum Pneumatic up-down seat,more convenient and more comfortable It is for the use of the digital imaging system of mouth Specification: Power supply:AC220V+10%,50Hz,1KVA Tube current:8mA Focus size:1.5mm Total filtration:2.5mmAL Exposure time:0.2-4sec Leak radiation:Outside one meter<0.002mGy/h (National standard:0.25mGy/h) Optional:Tube current:0.5mA Precautions 1. In order to operate safe, must be installed properly good ground. 2. X-ray machine due to small thermal capacity is limited, should pay attention to intermittent operation is recommended. 3. The machine only during exposure, will produce X-rays, power-off state does not produce X-rays, as long as it does not produce radiation exposure is not under power on state. 4. The machine is in the correct use, any unforeseen circumstances, please immediately cut off the power operator, discontinue use. After the aircraft maintenance standards, it can be used again.Additional filtration plate 5. The machine factory, each X-ray device is equipped with the following specifications: 1.0 / 0.5mm aluminum each one. 6. When disassembling the machine each time, first disassemble the nose and then split the other member. 8. After each use the machine, arm recovery highest point, the position of the head is placed equilibrium position.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.