Medical sterilizer HRLM-80
saturated steamon castersautomatic

Medical sterilizer - HRLM-80 - Haier Biomedical - saturated steam / on casters / automatic
Medical sterilizer - HRLM-80 - Haier Biomedical - saturated steam / on casters / automatic
Medical sterilizer - HRLM-80 - Haier Biomedical - saturated steam / on casters / automatic - image - 2
Medical sterilizer - HRLM-80 - Haier Biomedical - saturated steam / on casters / automatic - image - 3
Add to favorites
Compare this product
 

Characteristics

Applications
medical
Sterilization procedure
saturated steam
Configuration
on casters
Function
automatic
Capacity

80 l
(21.13 gal)

Temperature range

Max.: 136 °C
(276.8 °F)

Min.: 105 °C
(221 °F)

Width

546 mm
(21 in)

Height

1,085 mm
(42.7 in)

Depth

750 mm
(30 in)

Description

This upright automatic rapid sterilization unit uses high temperature saturated steam as the sterilization medium. Applicable to testing laboratories, laboratories, operating rooms, supply rooms, higher education, animal husbandry, disease control centers and other medical and biomedical research units, achieves rapid sterilization of instruments, dressings, rubber, liquids, glassware, bacteria and cell culture medium, wastes, etc. Product Features Automatic Program Control Water injection, heating, exhaust, sterilization, pressure relief, drainage, drying, automatic control of the whole process, no manual operation, one-click completion. Automatic Drying Function (Auxiliary Drying) The drying time can be set after the sterilization is completed. Multiple Exhaust Methods A variety of exhaust methods such as regular temperature setting exhaust, dynamic exhaust and full-process air escape, completely eliminates the cold air in the sterilizer and improves steam saturation, ensuring effective sterilization. One-click Start of Stored Procedures Equipped with quick programs for instruments, dressings, rubber and liquids, one-button start for easy operation. Two Pressure Relief Methods Two pressure relief methods are available: fast pressure relief and slow pressure relief. The slow pressure relief method for liquid sterilization can prevent liquid overflow caused by rapid buildup of pressure. Warm-up Control and Timing Start The preheating control function supports the sterilizer heating process, which shortens the heating time of the sterilizer and improves the efficiency of the process;