Medical sterilizer HG-5025E·P
testethylene oxidevertical

Medical sterilizer - HG-5025E·P - Hanshin Medical - test / ethylene oxide / vertical
Medical sterilizer - HG-5025E·P - Hanshin Medical - test / ethylene oxide / vertical
Medical sterilizer - HG-5025E·P - Hanshin Medical - test / ethylene oxide / vertical - image - 2
Medical sterilizer - HG-5025E·P - Hanshin Medical - test / ethylene oxide / vertical - image - 3
Medical sterilizer - HG-5025E·P - Hanshin Medical - test / ethylene oxide / vertical - image - 4
Add to favorites
Compare this product
 

Characteristics

Applications
medical, test
Sterilization procedure
ethylene oxide
Configuration
vertical
Function
automatic
Options
with sliding door
Capacity

250 l
(66.04 gal)

Temperature range

Min.: 5 °C
(41 °F)

Max.: 30 °C
(86 °F)

Width

872 mm
(34 in)

Height

1,801 mm, 1,803 mm
(70.9 in, 71 in)

Depth

1,300 mm, 1,350 mm
(51 in, 53 in)

Description

This sterilizer uses the "100% ethylene oxide(EO) gas" as sterilant and can sterilize conveniently many medical devices and instruments or bulky loads at once by convenient way of only inserting a small disposable gas cartridge on the holder recessed in the chamber wall. The sterilization and aeration process are all completed in the chamber under negative pressure, therefore leakage of EO gas in the working area can be fully prevented. 2. One-touching Operation of Vertical Automatic Sliding Door The vertical automatic sliding door moves up and down smoothly by one-touching the door control buttons on the touch screen, therefore sterilizing is much more safe and convenient than the hinged door type. Moreover it has an advantage of saving the required space for operating the sterilizer. The automatic sliding door is divided to the single door type and double door type, the advantage of double door is that the risk of recontamination after sterilization could be prevented because the sterilized loads are taken out at the clean area. 3. Various Cycle Programs and Self-diagnosis Function 4 kinds of sterilization cycle program and the vacuum leak test cycle program are installed in the sterilizer and the operator can select a proper cycle program according to the type of materials or items to be sterilized and sterilize them conveniently. If an error has occurred during operating the sterilizer, the error code is displayed on the touch screen accompanying an audible alarm and the cycle in progress is aborted at the same time automatically for the safety of workplace by the self-diagnosis program.