Medical sterilizer HG-700E·P
testethylene oxidebuilt-in

Medical sterilizer - HG-700E·P - Hanshin Medical - test / ethylene oxide / built-in
Medical sterilizer - HG-700E·P - Hanshin Medical - test / ethylene oxide / built-in
Medical sterilizer - HG-700E·P - Hanshin Medical - test / ethylene oxide / built-in - image - 2
Medical sterilizer - HG-700E·P - Hanshin Medical - test / ethylene oxide / built-in - image - 3
Medical sterilizer - HG-700E·P - Hanshin Medical - test / ethylene oxide / built-in - image - 4
Medical sterilizer - HG-700E·P - Hanshin Medical - test / ethylene oxide / built-in - image - 5
Add to favorites
Compare this product
 

Characteristics

Applications
medical, test
Sterilization procedure
ethylene oxide
Configuration
built-in
Capacity

700 l
(184.92 gal)

Temperature range

Max.: 30 °C
(86 °F)

Min.: 5 °C
(41 °F)

Width

1,255 mm
(49 in)

Height

1,880 mm
(74 in)

Depth

1,652 mm, 1,984 mm
(65 in, 78 in)

Description

This is the 100% EO gas sterilizer equipped with a large capacity of chamber for sterilizing the bulky or lots of medical devices, instruments and supplies at once by convenient way of only inserting two small disposable gas cartridge on the holder recessed in the chamber wall. The sterilization and aeration process are all completed in the chamber under negative pressure, therefore leakage of EO gas in the working area can be fully prevented. 2. Various Cycle Programs and Self-diagnosis Function 4 kinds of sterilization cycle program and the vacuum leak test cycle program are installed in the sterilizer and the operator can select a proper cycle program according to the type of materials or items to be sterilized and sterilize them conveniently. If an error has occurred during operating the sterilizer, the error code is displayed on the touch screen accompanying an audible alarm and the cycle in progress is aborted at the same time automatically for the safety of workplace by the self-diagnosis program. 3. Cycle Execution Data Storing and Retrieval Function At least 11 years of cycle execution records are automatically stored on the SD(secure digital) memory card of the control unit. The user can search and check the results of a cycle performed in the past by input the date performed or cycle count number on the touch screen, and print out the record by the built-in panel printer for using as an evidence data of sterilization quality.

Exhibitions

Meet this supplier at the following exhibition(s):

AEEDC 2025
AEEDC 2025

4-06 Feb 2025 Dubai (United Arab Emirates) Stand S1F08

  • More information