Fingertip pulse oximeter Prince-100A
compactmedicalhome care

Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care
Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care
Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care - image - 2
Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care - image - 3
Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care - image - 4
Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care - image - 5
Fingertip pulse oximeter - Prince-100A - Heal Force - compact / medical / home care - image - 6
Add to favorites
Compare this product
 

Characteristics

Configuration
fingertip, compact
Applications
medical, home care
Oxygen level

Max.: 100 %

Min.: 35 %

Description

Fingertip Oximeter Prince 100A can monitor SpO2 and PR through patient's finger. This device is applicable to hospital/clinics, home, oxygen bar, community medical center, alpine area, can also be used before/after exercise and so on. Features 1.Lightweight, easy to carry 2.1.1-inch LCD backlit screen 3.Ability to display blood oxygen saturation, pulse rate, perfusion index, Pulse Intensity Bar-graph 4.Display interface supports two-way rotation 5.Good performance under low perfusion, strong anti-interference ability 6.With smart power-saving mode that automatic shutdown after no signal for more than 8 seconds 7.With functions such as over-limit reminder and low battery reminder 8.Two AAA batteries for 50 hours of continuous use Parameters Oxygen Saturation (SpO2) Measurement Range: 35%~100% Display range: 35%~99% Measurement Accuracy: 70%~100%: ±2% 50%~69%: ±3% Alarm range: ≤90% Pulse Rate (PR) Measurement Range: 30bpm~240bpm Measurement Accuracy: ± 2bpm or ± 2%, whichever is greater PR Alarm Range: upper limit: 120bpm Lower limit alarm: 50bpm PR Deviation: ± 2% or ± 2bpm, whichever is greater Anti-interference Ability to Resist Natural Light Interference: The deviation of blood oxygen measurement values under indoor natural light and existing lighting sources is less than ± 1% compared with the measurement value in darkroom conditions. Resistance to Artificial Light Interference: accurate measurement of SpO2 and PR under test conditions of the pulse oximeter

VIDEO