Medical autoclave HRM-242Ⅱ
benchtophorizontalautomatic

Medical autoclave - HRM-242Ⅱ - HIRAYAMA - benchtop / horizontal / automatic
Medical autoclave - HRM-242Ⅱ - HIRAYAMA - benchtop / horizontal / automatic
Medical autoclave - HRM-242Ⅱ - HIRAYAMA - benchtop / horizontal / automatic - image - 2
Add to favorites
Compare this product
 

Characteristics

Applications
medical
Configuration
benchtop, horizontal
Function
automatic
Options
with dryer
Capacity

16 l
(4.23 gal)

Temperature range

Min.: 105 °C
(221 °F)

Max.: 134 °C
(273.2 °F)

Sterilization cycle time

Min.: 1 min

Max.: 60 min

Width

505 mm
(20 in)

Height

380 mm
(15 in)

Depth

535 mm
(21 in)

Description

Temperature and time can be set with easy operation. Selectable drying time Memory function Optimal drying is always possible. Features & Functions One-touch door interlock mechanism The sliding door latch system offers convenient, one-touch door opening and secure closing. For safety, the door cannot be opened while the chamber is pressurized. Automatic one-touch program selection Depending on the load to be sterilized, you can access from three preset programs at the touch of the MODE button: 1) Sterilization-Exhaust-Drying 2) Sterilization-Rapid exhaust (solids) 3) Sterilization-Exhaust (liquid) After selecting the desired program, merely pressing the START key will automatically initiate and complete the program from sterilization through drying (if selected). The default parameters in each program can be changed quickly from the keypad. Once changed, the new values are retained in memory until reprogrammed. Thus, the same cycle can be repeated merely by pressing the START key. Automatic steam exhaust system In the liquid cycle, the automatic exhaust system is activated after completion of sterilization, providing controlled, unattended rapid cooling down, but without the risk of boiling over. In the solid goods cycles, steam is exhaust more rapidly after sterilizati-on. Full sterilization with efficient drying The microprocessor executes the sterilization cycle with accurate and precise temperature control. An internal drying heater is used to dry the load more efficiently than an external heater.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.