Type
mass
Other characteristics
high-throughput
Length

615 mm
(24.2 in)

Width

510 mm
(20.1 in)

Height

615 mm
(24.2 in)

Weight

85 kg
(187.4 lb)

Description

In July 2019, an amendment to the RoHS directive will add 4 phthalates to the list of restricted substances. These 4 chemicals are widely used for insulated coating materials, electrical insulation tapes and packing films. The HM1000A is a dedicated instrument designed for fast, easy, on-site screening of phthalates. In addition to easy operation, the HM1000A features high-throughput testing that achieves automated analysis of 50 samples in approximately 8 hours. Features High-speed measurement:Measurement at a rate of less than 10 minutes! Vaporized compounds are ionized and directly analyzed by a mass spectrometer enabling high-speed measurement.(Separation column is not required) The auto sampler allows for continuous automated analysis of 50 samples in 8 hours The accurate and smooth performance of the auto sampler (standard equipment) allows continuous automatic analysis of up to 50 samples. During the analysis, operators are free to engage in other tasks, resulting in a streamlined operation and reducing workloads. Easy operation from sample preparation to analysis! Place the sample in the sample pan and position it on the sample tray. Next, by following simple software steps, measurements will be started by the auto sampler. The auto sampler diagram is displayed on the software and the progress of measurements and the results (PASS/FAIL judgment) can be verified easily. Low operating costs Nitrogen gas is used as the carrier gas. Using nitrogen gas generator (option available in Japan or locally sourced), a power source is the only utility required for operation. Helium gas and liquid nitrogen are not needed, which helps keep operating costs low.

Catalogs

No catalogs are available for this product.

See all of Hitachi High-Technologies‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.