Steam sterilizer HYZG series
medicalhorizontalbuilt-in

steam sterilizer
steam sterilizer
steam sterilizer
Add to favorites
Compare this product
 

Characteristics

Applications
medical
Sterilization procedure
steam
Configuration
horizontal, mobile, built-in
Function
automatic
Sterilization chamber material
stainless steel
Capacity

Max.: 180 l
(47.55 gal)

Min.: 50 l
(13.21 gal)

Temperature range

Max.: 138 °C
(280.4 °F)

Min.: 105 °C
(221 °F)

Width

480 mm, 540 mm, 650 mm
(19 in, 21 in, 26 in)

Height

1,450 mm, 1,550 mm
(57.1 in, 61 in)

Description

HYZG.B Fully Automatic Horizontal Pulse vacuum Autoclave is suitable fro sterilizing unwrapped.wrapped.solid. Hollow A,hollow B,instrument with built-in pipe and implanted instrument which can withstand high temperature and pressure. HYZG.N Fully Automatic Horizontal Non-Pulse vacuum Autoclave is suitable for sterilizing unwrapped,wrapped, dressing,rubber,liquid and lab instruments which can withstand high temperature and pressure Technical advantage 1.PLC control,sixty-five thousand color touch screen,powerful and reliable system. 2.Water injection,pulsing (special for pulse vacuum autoclave),heating up,sterilizing,drying process are fully automatic without artificial regulation 3.Stage,temperature,pressure,time and fault messages are shown on touch screen display. 4.Built-in micro-printer,record the whole sterilization information. 5.Cycle count function 6.Beep sound once,cycle end and messages shown on screen touch display 7.HYZG.B Fully Automatic Horizontal Pulse vacuum Autoclave with built-in high quality vacuum pump,1-6 times pulse vacuum can reach -0.09Mpa(-0.9Bar),to ensure effective removal of air of dressing.sterilization bag and hollow instrument so as to get the optimum saturate steam. 8.Inner circulation structure designed for HYZG.B fully Automatic Horizontal Pulse vacuum Autoclave ,water ring pump without external pipeline,easy to install 9.Unique pulse vacuum drying procedure designed for HYZG.B fully Automatic Horizontal Pulse vacuum Autoclave,residue moisture is less than 0.2% after drying Safety protection device 1.Heater protection:the system will cut off its power supply once the temperature exceeds the desired value and show the alarm information

Catalogs

No catalogs are available for this product.

See all of HYZMED Medical‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.